2 / 3 page ![]() standexelectronics.com Datasheet Rev ABA Page 2 +1 970.879.9900 | sensorsales@standexelectronics.com Environmental Specifications Corrosion Resistance 500 hours salt spray ASTM B-117 Installation Torque 23 Foot-Pounds Maximum Enclosure Nema 1,3,4,6,13 & IEC IP67 Vibration 10 G’s 2 to 2000 Hz Sinusodal Mechanical Shock 100 G’s, 11 mS Half-Sine S12H-275VPA-RGCB2 Analog Ferrous Metal Position Sensor Electrical Specifications Conditions Min Max Unit Temperature Range* Operating -40 +110* Deg C Supply Voltage, Vcc Operating +8 +30 Volts DC Supply Current Into Vcc 2.5 12 mA Output Current Recommended -2 +2 mA Load Capacitance Cable and Load n/a +1.0 µF Frequency Range ** Programmable 0 500** Hz Saturation Voltage Low I sink < 1.0 mA 0 .35 Volts Saturation Voltage High I source < 1.0 mA 4.65 Vcc Volts Impulse Response Time 500 Hz Freq. Range 2 typ 4 mS * T max = 150°C is available, contact factory. ** Can be programmed for operation 2000 Hz, contact factory. Functional Characteristics 900-12-000w/LargeSteel Target Min Typ Max For Sensors with Custom Programming, these values may change Voltage at Infinity 0.40V 0.50V 0.60V Voltage at 0” 4.25V 4.50V 4.75V Conformity to Curve -250V - +250V Rev A OTHER MATING CONNECTORS AND CABLES AVAILABLE Absolute Max Limits Min Max Unit Supply Voltage, Vcc -16 30 Volts Supply Voltage, <10 min -5 +8.5 Volts Continuous Output Current -10 +10 mA Vout Short Circuit Duration - 3 Minutes ESD -7 +7 kVolts Load Dump, 40 ms - 40 Volts Connections Chart Pin 1 Vcc Pin 3 Ground Pin 2 Analog Vout Pin 4 Program/LEAVE OPEN CB2-275VPA CB2, Integral 4 Pin Male 12mm Micro Connector Rev A 1 4 2 3 SENSOR BACKVIEW SHOWING PINS 12MM X 1 THREADS (PART OF HOUSING) ADDS 1MM TO HOUSINGLENGTH Note: Check our website or contact us for details on all our ferrous metal detection options. Caution:A short from the Pin 4 Program wire to either Pin 1 Vcc or Pin 3 Ground wire will cause component failure. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |