57 / 66 page ![]() H7CC-R @ 57 Replacement Time Notification Function The counter includes parts such as electrolytic capacitors and relays that deteriorate with time or with repeated operations. The H7CC is equipped with a function for notifying the replacement time by the cumulative run time and ON count of the relay contact. When either one of the deterioration of the electrolytic capacitors due to the cumulative run time or the deterioration of the relay contact due to the output ON count reaches the replacement time, Rplc (REPLACE) can be displayed on the Timer. For details on RPLC display, refer to Self-diagnosis Function on this page. Cumulative Run Time Alarm Set Value (ot-a) The cumulative run time can be set in a range from 0.0 to 99.9 years. The Replacement Time Notification Function is disabled if 0 is set. 10 years is set in the default settings. If the cumulative run time reaches the alarm set value or above, an RPLC (replacement time) error can be displayed on the Timer. The extent of deterioration of electrolytic capacitors varies depending on the capacitor temperature and usage period. According to the default settings, the ambient temperature is 35°C, the output load is 50%, and the utilization rate is 100%. If you are changing the actual usage conditions, enter the ambient temperature, output load, and utilization rate in the H7CC replacement time calculation tool available on the OMRON website to calculate the appropriate cumulative run time when the deterioration of electrolytic capacitors is expected. Output ON Count Alarm Set Value (on-a, on1a, on2a) Set the alarm value for the output ON count. The limit can be set between 0×1000 (0 times) and 9999×1000 (9,999,000 times). Only the underlined values are set. The alarm will be disabled if 0 is set. 100,000 times is set in the default settings. If the total output ON count reaches the alarm set value or above, an RPLC (replacement time) error can be displayed on the Timer. Self-diagnostic Function The following displays will appear if an error occurs. *1. This includes times when the life of the non-volatile memory has expired. *2. Occurs when the measurement value reaches 999,999. *3. Display flashes (1-second cycles). *4. The normal display and Rplc will appear alternately. When hold operation is performed, Rplc will not be displayed even if the alarm set value is exceeded. (Monitoring is possible, however, because the counter will continue without the cumulative run time and output ON count being cleared.) Rplc is displayed again if the power is turned OFF/ON after the Rplc display is cleared during recovery by the hold operation. If you do not want to display Rplc when the power is turned OFF/ON, either change the alarm set value to the present value or above, or change the alarm set value to 0 to disable it. Main display Sub-display Error Output status Correction method Set value after reset ffffff *3 No change Measurement value overflow *2 No change Measurement value ≤ 999999 No change e1 Not lit CPU OFF Either perform hold operation or reset the power supply. No change e2 Not lit Memory error (RAM) OFF Turn ON the power again. No change e2 sum Memory error (non-volatile memory) *1 OFF Hold operation Factory setting Rplc *4 No change The cumulative run time or output ON count reaches the replacement time No change Hold operation No change |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |