| 数据搜索系统,热门电子元器件搜索 |
|
LSP5523-R8A 数据表(PDF) 16 Page - Diodes Incorporated |
|
|
|||||||||||||||||||||||||||||
LSP5523-R8A 数据表(HTML) 16 Page - Diodes Incorporated |
|
16 / 17 page ![]() LSP5523 Document number: DS44073 Rev. 7 - 2 16 of 17 www.diodes.com May 2022 © 2022 Copyright Diodes Incorporated. All Rights Reserved. LSP5523 MSL (Moisture Sensitive Level) Information IPC/JEDEC J-STD-020D.1 Moisture Sensitivity Levels Table LEVEL FLOOR LIFE SOAK REQUIREMENTS Standard Accelerated Equivalent 7 eV 0.40-0.48 eV 0.30-0.39 CONDITION TIME CONDITION TIME (hours) CONDITION TIME (hours) TIME (hours) 1 Unlimited ≤30 °C /85% RH 168 +5/-0 85 °C /85% RH NA NA NA 2 1 year ≤30 °C /60% RH 168 +5/-0 85 °C /60% RH NA NA NA 2a 4 weeks ≤30 °C /60% RH 6968 +5/-0 30 °C /60% RH 120 -1/+0 168 -1/+0 60 °C/ 60% RH 3 168 hours ≤30 °C /60% RH 1928 +5/-0 30 °C /60% RH 40 -1/+0 52 -1/+0 60 °C/ 60% RH 4 72 hours ≤30 °C /60% RH 968 +2/-0 30 °C /60% RH 20 +0.5/-0 24 +0.5/-0 60 °C/ 60% RH 5 48 hours ≤30 °C /60% RH 728 +2/-0 30 °C /60% RH 15 +0.5/-0 20 +0.5/-0 60 °C/ 60% RH a 24 hours ≤30 °C /60% RH 488 +2/-0 30 °C /60% RH 10 +0.5/-0 13 +0.5/-0 60 °C/ 60% RH 6 Time on Label (TOL) ≤30 °C /60% RH TOL 30 °C /60% RH NA NA NA Note 7: CAUTION - To use the ‘‘accelerated equivalent’’ soak conditions, correlation of damage response (including electrical, after soak and reflow), should be established with the ‘‘standard’’ soak conditions. Alternatively, if the known activation energy for moisture diffusion of the package materials is in the range of 0.40 - 0.48 eV or 0.30 - 0.39 eV, the ‘‘accelerated equivalent’’ may be used. Accelerated soak times may vary due to material properties (e.g .mold compound, encapsulant, etc.). JEDEC document JESD22-A120 provides a method for determining the diffusion coefficient. Note 8: The standard soak time includes a default value of 24 hours for semiconductor manufacturer’s exposure time (MET) between bake and bag and includes the maximum time allowed out of the bag at the distributor’s facility. If the actual MET is less than 24 hours the soak time may be reduced. For soak conditions of 30 °C/60% RH, the soak time is reduced by 1 hour for each hour the MET is less than 24 hours. For soak conditions of 60 °C/60% RH, the soak time is reduced by 1 hour for each 5 hours the MET is less than 24 hours. If the actual MET is greater than 24 hours the soak time must be increased. If soak conditions are 30 °C/60% RH, the soak time is increased 1 hour for each hour that the actual MET exceeds 24 hours. If soak conditions are 60 °C/60% RH, the soak time is increased 1 hour for each 5 hours that the actual MET exceeds 24 hours. Mechanical Data Moisture Sensitivity: Level 3 per J-STD-020 Terminals: Finish – Matte Tin Plated Leads, Solderable per MIL-STD-202, Method 208 Weight: 0.081 grams (Approximate) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |