| 数据搜索系统,热门电子元器件搜索 |
|
ADM488ABRZ 数据表(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM488ABRZ 数据表(HTML) 13 Page - Analog Devices |
|
13 / 16 page ![]() Data Sheet ADM488A/ADM489A APPLICATIONS INFORMATION DIFFERENTIAL DATA TRANSMISSION Differential data transmission reliably transmits data at high rates over long distances and through noisy environments. Differential transmission nullifies the effects of ground shifts and noise signals, which appear as common-mode voltages on the line. Two main standards that specify the electrical charac- teristics of transceivers used in differential data transmission are approved by the EIA. The RS-422 standard specifies data rates up to 10 Mbps and line lengths up to 4000 ft. A single driver can drive a transmission line with up to 10 receivers. To cater to true multipoint communications, the RS-485 stan- dard was defined to meet or exceed the requirements of RS-422. It also allows up to 32 drivers and 32 receivers to be connected to a single bus. An extended common-mode range of −7 V to +12 V is defined. The most significant difference between the RS-422 and RS-485 is that the RS-485 drivers can be disabled, thereby allowing up to 32 receivers to be connected to a single line. Only one driver should be enabled at a time, but the RS-485 standard contains additional specifications to guarantee device safety in the event of line contention. CABLE AND DATA RATE The transmission line of choice for RS-485 communications is a twisted pair. Twisted pair cable tends to cancel common-mode noise and causes cancellation of the magnetic fields generated by the current flowing through each wire, thereby reducing the effective inductance of the pair. The ADM488A/ADM489A are designed for bidirectional data communications on multipoint transmission lines. A typical application with a multipoint transmission network is illustrated in Figure 22. An RS-485 transmission line can have up to 32 transceivers on the bus. Only one driver can transmit at a par- ticular time, but multiple receivers can be simultaneously enabled. As with any transmission line, it is important to minimize reflec- tions. This can be achieved by terminating the extreme ends of the line using resistors equal to the characteristic impedance of the line. Keep stub lengths of the main line as short as possible. A properly terminated transmission line appears purely resistive to the driver. Table 8. Comparison of RS-422 and RS-485 Interface Standards Specification RS-422 RS-485 Transmission Type Differential Differential Maximum Data Rate 10 Mbps 10 Mbps Maximum Cable Length 4000 ft. 4000 ft. Minimum Driver Output Voltage ±2 V ±1.5 V Driver Load Impedance 100 Ω 54 Ω Receiver Input Resistance 4 kΩ minimum 12 kΩ minimum Receiver Input Sensitivity ±200 mV ±200 mV Receiver Input Voltage Range −7 V to +7 V −7 V to +12 V Number of Drivers/Receivers per Line 1/10 32/32 D R D R D R RT RT D R Figure 22. Typical RS-485 Network Rev. B | Page 13 of 16 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |