| 数据搜索系统,热门电子元器件搜索 |
|
USB-PDISO8/40 数据表(PDF) 8 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
USB-PDISO8/40 数据表(HTML) 8 Page - List of Unclassifed Manufacturers |
|
8 / 10 page ![]() Measurement Computing (508) 946-5100 8 info@mccdaq.com mccdaq.com USB DIO High Voltage and Relay I/O Module Configuratio USB-SSR08 Modules 1-4: Selectable with switch S1 in the CL position as either input or output (default) modules. Switch settings for direction can be read back with software. Do not mix input and output modules within this bank of four. Modules 5-8: User-selectable with switch S1 in the CH position as either input modules or output (default) modules. Switch settings for direction can be read back with software. Do not mix input and output modules within this bank of four. USB-SSR24 Modules 1-8: Selectable with switch S1 in the A position as either input or output (default) modules Switch settings for direction can be read back with software. Do not mix input and output modules within this bank of eight. Modules 9-16: Selectable with switch S1 in the B position as either input modules or output (default) modules. Switch settings for direction can be read back with software. Do not mix input and output modules within this bank of eight. Modules 17-20: Selectable with switch S1 in the CL position as either input or output (default) modules. Switch settings for direction can be read back with software. Do not mix input and output modules within this bank of four. Modules 21-24: Selectable with switch S1 in the CH position as either input or output (default) modules. Switch settings for direction can be read back with software. Do not mix input and output modules within this bank of four. I/O module logic polarity: Selectable with switch S2. Switch settings for polarity can be read back with software. Default to non-inverted. For input modules, invert mode returns a 1 when module is active; non-invert mode returns a 0 when module is active. For output modules, invert mode allows users to write a 1 to activate the module; non-invert mode allows users to write a 0 to activate the module. Pull-up/pull-down on digital I/O lines: Configurable with switch S3 with 2.2 kΩ resistor network. Switch settings for pull-up/pull-down selection can be read back with software. Default to pull-up. Switch settings are applicable during power up conditions of output modules only. Modules are active Low. When switch to Pull-up, modules are inactive on power up. When switched to pull- down, modules are active on power up. Power USB +5 V input voltage range: 4.75 V min to 5.25 V max USB +5 V supply current (all modes of operation) USB-SSR08: <100 mA USB-SSR24: 10 mA max External power supply (included; required for USB-SSR24): MCC p/n CB-PWR-9 9 V @ 1.67 A Voltage supervisor limits - PWR LED 6.0 V > Vext or Vext > 12.5 V: PWR LED = Off (power fault) 6.0 V ≤ Vext < 12.5 V: PWR LED = On USB-SSR24 Block Diagram Bidiectional Buffer 4 Bidiectional Buffer 4 Bidiectional Buffer 8 Bidiectional Buffer Load 8 USB Microcontroller 500 mA USB 2.0 Compliant Interface Power Regulator Power Monitor 9.0 V External Power Switch S1 (I/O Type) Switch S3 (Pull-Up/Down) Switch S2 (Inv/Non-Inv) SSR Modules 1-8 (Port A) SSR Modules 9-16 (Port B) SSR Modules 17-20 (Port CL) SSR Modules 21-24 (Port CH) Specifications - USB-SSR Series |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |