| 数据搜索系统,热门电子元器件搜索 |
|
FD-R32EG 数据表(PDF) 23 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
FD-R32EG 数据表(HTML) 23 Page - List of Unclassifed Manufacturers |
|
23 / 28 page ![]() 161 DigitalFiberSensorFX-300SERIES Selection Guide Fibers Fiber Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS For FX-305(P) The FX-305(P) is equipped with two independent outputs, but the items that can be set in output 1 and output 2 respectively are only the following. The items other than those are common. 1 Threshold value 2 Output operation 3 Timer operation and Timer period 4 Sensing mode Teaching • The threshold values can be set by 2-point teaching, limit teaching, full-auto teaching or window comparator mode (1-point, 2-point, 3-point teaching) [only for FX-305(P)], when the MODE indicator / TEACH (yellow) lights up. • This is the method of setting the threshold value by teaching two levels, corresponding to the object present and object absent conditions. Normally, setting is done by this method. Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-305(P), select either Output 1 “ ” or Output 2 “ ” beforehand, press jog switch in the object present condition. If the teaching is accepted, the read incident light intensity blinks in the digital display. Beam blocked condition Thru-beam type Reflective type Mark Background MODE indicator / TEACH (yellow) blinks. Press jog switch in the object absent condition. Beam incident condition Mark Background Thru-beam type Reflective type If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the mid- value between the incident light intensities in the object present and the object absent conditions. After this, the judgment on the stability of sensing is displayed. • In case stable sensing is possible: “ ” is displayed. • In case stable sensing is not possible: “ ” blinks. The threshold value is displayed. “ ” blinks in the digital display. (only FX-301B/G/H) The incident light intensity appears in the digital display and the setting is complete. Notes: 1) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. 2) In case a reflective-type fiber is used, maximum sensitivity will be set if the jog switch is pushed while in no work status in procedure and . Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-305(P), select either Output 1 “ ” or Output 2 “ ” beforehand, press the jog switch continuously for 0.5 sec. or more with the object moving on the assembly line. (The incident light intensity is displayed during sampling.) “ ” is displayed on the digital display. Release the jog switch when the object has passed. If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the mid- value between the incident light intensities in the object present and the object absent conditions. After this, the judgment on the stability of sensing is displayed. • In case stable sensing is possible: “ ” is displayed. • In case stable sensing is not possible: “ ” blinks. The threshold value is displayed. “ ” blinks in the digital display. (only FX-301B/G/H) The incident light intensity appears in the digital display and the setting is complete. Notes: 1) The threshold value’s shift amount can be selected in PRO mode. Refer to the “PRO Mode Operation Guide” for more details pertaining to setting instructions. (Increments of 5 % between –45 and 45 % for setting possible. 0 % default.) 2) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. In case of 2-point teaching • Full auto-teaching is used when it is desired to set the threshold value without stopping the assembly line, with the object in the moving condition. In case of full auto-teaching Refer to p.1458~ for general precautions and to the “PRO mode operation guide” on our website for details pertaining to operating instructions for the amplifier. PRECAUTIONS FOR PROPER USE |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |