数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

7614-6002 数据表(PDF) 23 Page - Renesas Technology Corp

部件名 7614-6002
功能描述  E2 emulator Lite RTE0T0002LKCE00000R User’s Manual
PDF  36 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  RENESAS [Renesas Technology Corp]
网页  http://www.renesas.com
标志 RENESAS - Renesas Technology Corp

7614-6002 数据表(HTML) 23 Page - Renesas Technology Corp

Back Button 7614-6002 Datasheet HTML 19Page - Renesas Technology Corp 7614-6002 Datasheet HTML 20Page - Renesas Technology Corp 7614-6002 Datasheet HTML 21Page - Renesas Technology Corp 7614-6002 Datasheet HTML 22Page - Renesas Technology Corp 7614-6002 Datasheet HTML 23Page - Renesas Technology Corp 7614-6002 Datasheet HTML 24Page - Renesas Technology Corp 7614-6002 Datasheet HTML 25Page - Renesas Technology Corp 7614-6002 Datasheet HTML 26Page - Renesas Technology Corp 7614-6002 Datasheet HTML 27Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 36 page
background image
E2 Lite
Setup
R20UT3240EJ0300 Rev.3.00
Page 23 of 36
May.15.20
2.4
Turning the Power On/Off
Turn the power of the E2 Lite and the user system following the procedure below.
2.4.1
When a Separate Power Supply is Used for the User System
<When using the emulator>
(1) Check that the power is off.
Check that the user system is turned off.
(2) Connect the user system.
Follow the instructions in "2.3 Connecting the E2 Lite to the User System" to connect the emulator and
the user system with a user-system interface cable.
(3) Connect the host machine and turn on the emulator.
Follow the instructions in "2.2 Connecting the E2 Lite to the Host Machine" to connect the emulator and
the host machine with a USB interface cable. The E2 Lite is turned on by connecting the USB interface
cable.
(4) Launch the emulator debugger or programming software.
(5) Turn on the user system.
(6) Connect the emulator debugger or programming software to the E2 Lite.
The method of connection may differ with the software.
<When finished using the emulator>
(1) Disconnect the E2 Lite from the emulator debugger or programming software.
Disconnections may differ with the software.
(2) Turn off the user system.
(3) Close the emulator debugger or programming software.
(4) Turn off and disconnect the emulator.
The E2 Lite is turned off by disconnecting from the USB interface cable.
(5) Disconnect the user system.
Disconnect the user-system interface cable from the user system.
CAUTION
Note on the User System Power Supply:
While the power of the user system is on, do not turn off the host machine or unplug the USB
interface cable.
The user system may be damaged due to leakages current.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com