| 数据搜索系统,热门电子元器件搜索 |
|
JS20 数据表(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
JS20 数据表(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 17 page ![]() Precautions Mounting Warning Specifications Basic type, Flange type, Foot type Mounting Operating range JA 3-050 4-070 5-080 6-100 8-125 10-125 14-150 18-150 22-150 26-150 30-150 36-150 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M30 x 1.5 M36 x 1.5 40 F 14-150 6 10 10, 15 20 25, 32 40 50, 63 80 100 125, 140 160 180 200 Model/Specifications None Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions. Operating pressure Pneumatic cylinder: 1 MPa or less Hydraulic cylinder: 3.5 MPa or less Center of sphere Axial center 1. To screw the male threads of the rod into the female threads of the socket or the case, make sure that it does not bottom out. If the floating joint is used with its rod bottom out, the stud will not be able to float, causing damage. For the screw-in depth of the female threads, refer to the dimensions (page 1146). As a rule, after the rod bottoms out, back off 1 to 2 turns. 2. The dust cover may adhere to the stud. In this case, move the dust cover at the neck of the stud by the finger or twist the stud slightly left or right to break in the dust cover before use. Additionally, when screwing the stud and socket or the case into a driven body, screw in such parts with the dust cover removed. When screwing in such parts without removing the dust cover, this may cause damage to the dust cover. 3. To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive. In the event that the connected portion becomes loose, the driven body might lose control or fall off, leading to equipment damage or injury to personnel. 4. This product is not a rotary joint. So, the product cannot be used for rotational or rotation acting applications. 5. Be sure to use the cushion mechanism of the cylinder or the buffer mechanism, such as the shock absorber so that any impact force is not applied to the floating joint when stopping a driven body. If there is no buffer mechanism, an excessive impact force is generated. As a result, the tensile compression force of the floating joint may exceed its maximum level. How to Order Mounting type Nil F L Basic type Flange type Foot type Applicable bore size (mm) Symbol Applicable bore size (mm) Model Thread nominal size (Standard) Nominal thread size Applicable cylinder nominal thread size Option X11 Nil High temperature specifications –5 to 100 °C Floating Joint: Standard Type JA Series RoHS Maintenance Warning 1. Do not reuse if disassembled. High strength adhesive is applied to the portion of the connection that is threaded to prevent it from loosening, and it must not be disassembled. If it is forcefully disassembled, it could lead to damage. JA series Made to Order: Individual Specifications -X530 Note) For details, refer to page 1149. For pneumatic cylinders 6 10 15 20 30 40 63 80 100 140 160 180 200 Model Applicable bore size (mm) Applicable cylinder nominal thread size Rotating angle Ambient temperature Allowable eccentricity U (mm) Maximum operating tension and compression force (N) Basic type Flange type Foot type Standard/Thread nominal size Semi-standard/Thread nominal size JA6-3-050 JA10-4-070 JA15-5-080 JA15-6-100 JA 20-8-125 JA 30-10-125 JA 40-14-150 JA 63-18-150 JA 80-22-150 JA 100-26-150 JA 140-30-150 JA 160-36-150 6 10 10, 15 15 20 25, 32 40 50, 63 80 100 125, 140 160 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M30 x 1.5 M36 x 1.5 19 54 123 123 1100 2500 4400 11000 18000 28000 54000 71000 – – – – 1100 2500 4400 11000 18000 28000 36000 55000 – – – – 1000 2000 4400 9000 14000 22000 36000 55000 0.5 0.5 0.5 0.5 0.5 0.5 0.75 1 1.25 2 2.5 3 JA 20-8-100 JA 25-10-150 JA 32-10-100 JA 40-12-125 JA 40-12-150 JA 40-12-175 JA 50-16-150 JA 63-16-200 JA 80-20-250 JA 100-24-300 JA 100-27-150 JA 125-27-200 JA 160-33-200 20 25 32 32, 40 40 32, 40 50 50, 63 80 100 100 125 160 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 M20 x 2.5 M24 x 3 M27 x 1.5 M27 x 2 M33 x 2 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000 28000 28000 71000 1100 2500 2500 4400 4400 4400 11000 11000 18000 28000 28000 28000 55000 1000 2000 2000 4400 4400 4400 9000 9000 14000 22000 22000 28000 55000 0.5 0.5 0.5 0.75 0.75 0.75 1 1 1.25 2 2 2 3 ±5° ±5° -5 to 60 °C 1. The black zinc chromate treatment is applied to the material surfaces of the case, flange and foot. However, the white deposit may rarely occur on the surface. This white deposit does not affect the product functions. However, if the white deposit becomes a problem from a viewpoint of appear- ance, special products with the surface treatment changed to the electroless nickel plating are also available. For details, please contact SMC. Caution 1144 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |