3 / 5 page

CHT-LDOS - Preliminary datasheet
Version 1.0 (17/05/2006)
http://www.cissoid.com
3
Output Load, recommended specifications
CHT-LDOS
CHT-LDOS
Resistances in series with capacitors represent the internal ESR of these capacitors.
For large capacitors:
For small Capacitors:
CB= 0 to 1000µF
CS= 100n to 220nF
RB= 0.2 to ∞ Ω
RS=10m to 50m Ω
For medium capacitors:
CM= 0 to 6µF
RM=0.1 to 1 Ω
Start-up conditions
The start-up is operative over the whole temperature range.
Refer to our application note for more details when using symmetrical voltages.
•
AN-06016: “Selecting correct CISSOID regulator depending on your application”
•
AN-06002: “Voltage regulator short-circuit protection and associated potential startup
problem”.