13 / 24 page ![]() LTC4100 13 sn4100 4100is OPERATIO Purpose: This function allows the SMBus Host to deter- mine if the battery charger is an LTC4100. Identifying the manufacturer and version of the Smart Battery Charger permits software to perform tasks specific to a given charger. The LTC4100 also provides a means of disabling the LOWI current mode of the IDAC. • SMBus Protocol: Write Word. Input: The NO_LOWI is the only bit recognized by this function. The default value of NO_LOWI is zero. The LTC4100 LOWI current mode provides a more accurate average charge current when the charge current is less than 1/16 of the full-scale IDAC value. When the NO_LOWI is set, a less accurate IDAC algorithm is used to generate the charging current, but because the charger is not pulsed on and off, it may be preferred. • SMBus Protocol: Read Word. Output: The NO_LOWI indicates the IDAC mode of opera- tion. If clear, then the LOWI current mode will be used when the charging current is less than 1/16 of the full- scale IDAC value. The LTC Version Identification will always be 0x202 for the LTC4100. Alert Response Address (ARA) Description: The SMBus system host uses the Alert Response Address to quickly identify the generator of an SMBALERT# event. Purpose: The LTC4100 will respond to an ARA if the SMBALERT signal is actively pulling down the SMBALERT# bus. The LTC4100 will follow the prioritization reporting as defined in the System Management Bus Specification, Version 1.1, from the SBS Implementers Forum. • SMBus Protocol: A 7-bit Addressable Device Re- sponds to an ARA. Output: The Device Address will be sent to the SMBus system host. The LTC4100 Device address is 0x12 (or 0x09 if just looking at the 7-bit address field). The following events will cause the LTC4100 to pull-down the SMBALERT# bus through the SMBALERT pin: • Change of AC_PRESENT in the ChargerStatus() func- tion. • Change of BATTERY_PRESENT in the ChargerStatus() function. • Setting ALARM_INHIBITED in the ChargerStatus() function. • Internal power-on reset condition. SMBus Accelerator Pull-Ups Both SCL and SDA have SMBus accelerator circuits which reduce the rise time on systems with significant capaci- tance on the two SMBus signals. The dynamic pull-up circuitry detects a rising edge on SDA or SCL and applies 1mA to 10mA pull-up to VDD when VIN > 0.8V until VIN < VDD – 0.8V (external pull-up resistors are still required to supply DC current). This action allows the bus to meet SMBus rise time requirements with as much as 250pF on each SMBus signal. The improved rise time will benefit all of the devices which use the SMBus, especially those devices that use the I2C logic levels. Note that the dynamic pull-up circuits only pull to VDD, so some SMBus devices that are not compliant to the SMBus specifications may still have rise time compliance problems if the SMBus pull- up resistors are terminated with voltages higher than VDD. The Control Block The LTC4100 charger operations are handled by the control block. This block is capable of charging the se- lected battery autonomously or under SMBus Host con- trol. The control block can request communications with the system management host (SMBus Host) by asserting SMBALERT = 0; this will cause the SMBus Host, if present, to poll the LTC4100. The control block receives SMBus slave commands from the SMBus interface block. The control block allows the LTC4100 to meet the follow- ing Smart Battery-controlled (Level 2) charger requirements: 1. Implements the Smart Battery’s critical warning mes- sages over the SMBus. 2. Operates as an SMBus slave device that responds to ChargingVoltage() and ChargingCurrent() commands and adjusts the charger output parameters accordingly. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |