| 数据搜索系统,热门电子元器件搜索 |
|
MAS9191EB 数据表(PDF) 3 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS9191EB 数据表(HTML) 3 Page - Micro Analog systems |
|
3 / 16 page ![]() 3 DA9191EB.006 June 30,1997 EVALUATION SOFTWARE x Help Pressing “#" will display instructions for the keys shown on the LCD. Press EXIT to return to the main menu. x Main menu The FORWARD and BACKWARD keys will select “register read”, “register write”, “message send” or “message read”. The given function is executed by pressing ENTER. x Register write When entering this function the register address will be shown at the top right. After entering the write function, pressing “#' will automatically set the default values (gain controls at nominal levels and necessary switches in proper positions) to measure the transmit and receive frequency responses. The register address can be changed with the FORWARD and BACKWARD keys. The lower line will show the current contents of the register. Press EXIT to return to the main menu. The ENTER key will remove the brackets around the register address and the cursor will move to the first nibble of the hex byte on the lower line. The UP and DOWN keys will increment or decrement the nibble. If the value of the register has been changed there will be an asterisk next to the register address. The FORWARD and BACKWARD keys will move the cursor left and right, respectively. When the cursor points to a bit of a register the TOGGLE key will change the value of the bit. After a bit has been edited the top line will display the function of the bit. The ENTER key will write any new values to the MAS9191A. Press EXIT to exit from the editing mode. If the function is terminated without writing any new values, the previous values are retained. x Register read This function is quite similar to the register write function. The register address is selected with FORWARD and BACKWARD keys from the main menu. The register can be read with the ENTER key. Pressing the ENTER key a second time will update the contents of the status register. The FORWARD and BACKWARD keys will move the cursor and display the function of each bit. Return to the top line or to the main menu with the EXIT key. x Message receive This function waits for 10 messages to be received. When the messages are received they can be examined with the FORWARD and BACKWARD keys. The function can be terminated with the EXIT key. An >N= in the upper right hand corner indicates NAMPS mode. x Message send In this function six messages can be entered. First the desired message number must be chosen with the FORWARD and BACKWARD keys. Then the ENTER key will advance to the edit mode. With the FORWARD and BACKWARD keys the nibbles of each byte can be chosen and the value incremented or decremented with the UP and DOWN keys. The ENTER key will store the message into memory. The EXIT key will move the cursor to the upper row. After all messages are edited the LCD reads "SEND MESSAGES". The ENTER key will move the cursor to the lower row and the FORWARD and BACKWARD keys will choose the message. The TOGGLE key will alternate between the plus and minus signs. The plus sign indicates that the message will be transmitted. When all messages are chosen the ENTER key will start the transmission, and may be done repeatedly. The transmission can be terminated with the EXIT key. An >N= in the upper right hand corner indicates NAMPS mode. xMicro Controller and Interfaces The 68HC11 micro controller can be reset with the reset button, with DTR or by switching power off and on. In the last case the voltage regulator internal reset circuit will perform the reset. When the MOD jumper is open the controller executes the software from the FLASH ROM. When the jumper is closed the controller enters the boot-strap mode after reset. In this mode the software which contains the hl.exe program can be loaded into the FLASH ROM or SRAM through the RS-232-C interface. The syntax of the software is: el [-p<X>] <filename> Where X is the serial port number: 1 for COM1 and 2 for COM2 and the file name is the same as the S-record file without the extension. For downloading the serial cable with the following connections are needed: PC MAS9191A 2 ----- 2 3 ----- 3 7 ----- 7 20 ----- 20 More information about the 68HC11 is available from the reference manual. P9 contains six inputs to the micro controller port PE. These inputs can be used as digital inputs or as analog inputs for the A/D-converter. When the micro controller is writing to address 0x1FFC and 0x1FFD the data is also written to the LCD command register. Write cycles to memory address 0x1FFD also change the state of the port at 0x1FFE. The port has eight outputs, ground and supply voltage. The maximum load for the power supply pin is 20 mA when operating at 3V. Keypad interface is done with port PA. Pins PA0, PA1 and PA2 are inputs from the 4x3 keypad and pins PA3-PA6 are outputs to the matrix. PA7 is the output pulse for MAS9129 watchdog circuit. All PA outputs are driven with the external buffer IC3. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |