| 数据搜索系统,热门电子元器件搜索 |
|
MP8794GLE 数据表(PDF) 13 Page - MPS Industries, Inc. |
|
|
|||||||||||||||||||||||||||||
MP8794GLE 数据表(HTML) 13 Page - MPS Industries, Inc. |
|
13 / 22 page ![]() MP8794 – 16V, 20A, SYNCHRONOUS STEP-DOWN CONVERTER MP8794 Rev. 1.0 www.MonolithicPower.com 13 12/2/2019 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2019 MPS. All Rights Reserved. OPERATION Constant-On-Time (COT) Control The MP8794 employs constant-on-time (COT) control to achieve a fast load transient response. Figure 2 shows the details of the control stage of the MP8794. The operational amplifier (AMP) corrects any voltage errors between the feedback voltage (VFB) and the reference voltage (VREF). The MP8794 can use AMP to provide excellent load regulation over the entire load range in either forced continuous conduction mode (CCM) or pulse skip mode. The dedicated VSNS- pin provides differential output voltage remote sensing. The remote- sense trace pair should be kept at low impedance for optimal performance. The MP8794 uses internal ramp compensation to support a low-ESR MLCC output capacitor solution. The adaptive internal ramp is optimized so that the MP8794 is stable across the entire operating input and output voltage ranges with a proper design of the output L/C filter. Adaptive Ramp On Timer PWM COMP + VREF FB PWM Comparator VSNS- AMP VSENS+ VSENS- Σ + L COUT VIN PGND SW HS-FET LS-FET Figure 2: COT Control Pulse-Width Modulation (PWM) Operation Figure 3 shows the generation of the pulse- width modulation (PWM) signal. AMP corrects any error between FB and REF, and generates a fairly smooth DC voltage (COMP). The internal ramp is superimposed onto COMP when compared to the FB signal. When VFB drops below the superimposed COMP, the integrated high-side MOSFET (HS- FET) turns on. The HS-FET remains on for a fixed on time. The fixed on time is determined by the input voltage, output voltage, and selected switching frequency. After the on time elapses, the HS-FET turns off. It turns on again when VFB drops below the superimposed COMP. By repeating this operation, the MP8794 regulates the output voltage. To minimize conduction loss, the integrated low-side MOSFET (LS-FET) turns on when the HS-FET is off. A dead short occurs between VIN and PGND if both the HS-FET and the LS- FET are turned on at the same time. This is called shoot-through. To avoid shoot-through, a dead time (DT) is generated internally between the HS-FET off period and LS-FET on period, or vice versa. PWM REF RAMP FB COMP tON HS-FET Driver LS-FET Driver IL IO Figure 3: Heavy-Load Operation (PWM) CCM Operation Continuous conduction mode (CCM) occurs when the output current is high, and the inductor current is always above 0A (see Figure 3). The MP8794 can be configured to operate in forced CCM operation when the output current is low (see the Mode Selection section on page 14 for details). In CCM operation, the switching frequency is fairly constant (PWM mode), so the output ripple remains almost constant throughout the entire load range. Pulse Skip Operation In light-load conditions, the MP8794 can be configured to work in pulse skip mode to optimize efficiency. When the load decreases, the inductor current also decreases. Once the inductor current reaches zero, the MP8794 transitions from CCM to pulse skip mode if the MP8794 is configured in this way (see the Mode Selection section on page 14 for details). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |