| 数据搜索系统,热门电子元器件搜索 |
|
UR132-22-AF5-3-R 数据表(PDF) 3 Page - Unisonic Technologies |
|
|
|||||||||||||||||||||||||||||
UR132-22-AF5-3-R 数据表(HTML) 3 Page - Unisonic Technologies |
|
3 / 4 page ![]() UR132 LINEAR INTEGRATED CIRCUIT UNISONICTECHNOLOGIESCO.,LTD 3 of 4 www.unisonic.com.tw QW-R102-007,G ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL RATING UNIT Input Voltage VIN -0.3~12 V Power Dissipation PD 300 mW Junction Temperature TJ +125 °C Operation Temperature TOPR -20~+125 °C Storage Temperature TSTG -40~+150 °C Note: 1.Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2.The device is guaranteed to meet performance specification within 0℃ ~ +70℃ operating temperature range and assured by design from -20℃ ~ +125℃. ELECTRICAL CHARACTERISTICS(Ta=25°C, CIN=1µF, COUT=10µF, unless otherwise specified) FOR VOUT<3.3V (VOUT±2%) PARAMETER SYMBOL TEST CONDITIONS MIN TYP. MAX UNIT Output Voltage VOUT IL=2mA, VIN-VOUT=2V VOUT×0.98 VOUT VOUT×1.02 V Output Voltage Temperature Coefficient TCVO 50 150 PPM/ °C Line Regulation △ VOUT IL=2mA, VIN-VOUT=2V~VIN=9V 0.5 %VOUT Load Regulation (note 2) △ VOUT IL=2mA~200mA, VIN-VOUT =2V 10 30 mV Current Limit (note 3) IL VIN-VOUT=2V, VOUT=0V 300 mA Dropout Voltage (note 4,5) VD 1.5 V Standby current ISTN-BY IL=0, VIN=9V 3.0 mA FOR ADJ and VOUT≧3.3V (VOUT±2%) PARAMETER SYMBOL TEST CONDITIONS MIN TYP. MAX UNIT Output Voltage VOUT IL=2mA, VIN-VOUT=2V VOUT×0.98 VOUT VOUT×1.02 V Adjustable (R1=120Ω,R2=200Ω,VOUT=3.3V) Reference Voltage VREF VIN-VOUT=2V, IL=2mA 1.238 1.250 1.262 V Output Voltage Temperature Coefficient TCVO 50 150 PPM/ °C Line Regulation △ VOUT IL=2mA, VIN-VOUT=2V~VIN=12V 0.5 %VOUT Load Regulation (note 2) △ VOUT IL=2mA~200mA, VIN-VOUT=2V 10 30 mV Current Limit (note 3) IL VIN-VOUT=2V, VOUT=0V 300 mA Dropout Voltage (note 4,5) VD 1.3 V Standby current ISTN-BY IL=0, VIN=12V 5.0 mA Note 1: Guaranteed by design. Note 2: Regulation is measured at constant junction temperature, using pulsed on time. Note 3: Current limit is measured at constant junction temperature, using pulsed on time. Note 4: Dropout is measured at constant junction temperature, using pulsed on time, and the criterion is VOUT inside target value ±2%. Note 5: Dropout test is skipped at the condition of VIN<3V. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |