| 数据搜索系统,热门电子元器件搜索 |
|
DMS-30DR-0-R-C 数据表(PDF) 4 Page - Delta Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
DMS-30DR-0-R-C 数据表(HTML) 4 Page - Delta Electronics, Inc. |
|
4 / 6 page ![]() S U N L I G H T R E A D A B L E , A U T O - D I M M I N G L E D D I S P L A Y M E T E R S DMS-30DR Series S U N L I G H T R E A D A B L E , A U T O - D I M M I N G L E D D I S P L A Y M E T E R S Figure 3. Differential Input Configuration R2 R1 + R2 x VIN = Reading 50k Ω < R1 + R2 < 10MΩ Figure 6. Floating Input Measurements (Alternate Configuration) Figure 5. Floating Input Measurements Figure 4. Input Attenuation Circuit RShunt = R1 = VFsr / IFsr Where: VFsr = Full scale reading (in Volts) IFsr = Relative full scale current (in Amps) 5. Process Control (4-to-20mA) Measurements: In many common pro- cess-control applications, a 4-to-20mA current loop is used to transmit information. Because DMS-30DR meters have such high input imped- ance, a simple shunt resistor across the meter's input can be used to convert the loop current to a voltage. See Figure 7. The value of the shunt resistor is a function of the scaling requirements of the particular application and can be calculated using the following equation: 2. Differential Input Configurations: Differential measurements can be made with all DMS-30DR meters. Figure 3, though not a practical real- world application, uses a voltage divider to demonstrate the concept of a differential input signal. Be careful not to exceed the ±2V common mode voltage limitation for 5V-powered meters. 3. Engineering Scaling: For measuring voltages greater than the full scale input range of a given meter, the input signal must be attenuated. A simple voltage divider (similar to that shown in Figure 4) will scale the input to within the range of the selected meter. R1 and R2 should be precision, ±1%, metal-film resistors with absolute TCR's less than 50ppm/°C. See Ap Note 4 for more information on engineering scaling. 4. Floating Signal Source Measurements: Floating signals can be measured using the circuits shown in Figures 5 and 6. Connecting pin 10 (ANALOG COMMON) or pin 3 (5V RETURN) to (–) INPUT LO (pin 12) provides the reference point for the meter's input. A "floating" input is a signal that has no galvanic connection to the meter's power supply. In the figures below, the 1.5V battery illustrates a true floating input. � �� � ������� ��������� ������ �� ��������� � ������������������ �� �� �� �� �� �� � � ������ ��� ������� ���������� ���������� ��������� �� �� �� ��������� ��������� ��� �� � � � ������� ������ ������������������ � � ������� ������ ���������� ���������� ��������� � � ������� ������ � ��� ������������������ ���������� �� ��������� �� ��������� ���� ���� � � ������� ������ � ���������� ��������� � � ������ � ��� �� ��������� �� �������� �� ��������� ���� ���� � � � ������� ������ ���������� ������� ������������������ ���������� ��������� MPM_DMS-30DR_A01 Page 4 of 6 D I G I T A L P A N E L M E T E R S www.cd4power.com APPLICATIONS |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |