4 / 62 page ![]() Surge Pr otective Devices 16.2 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 16 16 What is a transient surge? A transient surge is a sudden (shorter than a millisecond) rise in the flow of power. Voltage can peak at 12x the nominal system voltage. Transient surges result from a number of sources, the most common of which are internal, such as load switching and even normal equipment operations. In fact, approximately 80% of transients are generated internally. External transients are the result of lightning and load switching by utilities and upstream facilities. Internal load switching Switching on/off any elements that create a sudden variation of load will also cause a sudden change in current flow and generate transient surges. Lightning strikes A lightning strike (direct or indirect) can have a destructive or disturbing effect on installations located up to several miles from the actual point of the strike. During a storm, underground cables can transmit energy from a lightning strike to equipment installed inside buildings. A lightning protection device (such as a lightning rod or Faraday cage) installed on a building to protect against the risk of a direct strike can increase the risk of damage to electrical equipment connected to the main power supply near or inside the building. The lightning protection device diverts the high strike current to ground, considerably raising the potential of the ground close to the building on which it is installed. This causes overvoltages on the electrical equipment directly via the ground terminals and induced via the underground supply cables. Switching effects on power distribution The switching of transformers, motors or inductances in general, variation of load, disconnection of circuit breakers or cut outs lead to overvoltages that penetrate a building. The closer the building is to a generating station, substation or upstream switching point, the higher the overvoltages may be. Facilities and operations left unprotected are highly susceptible to the damaging effects of transients. Such as: • Catastrophic equipment failure • Immediate operation shutdown • Long term disruption of business • Expensive equipment repair and replacement • Data losses, system resets and network down time In order to ensure protection from transient surges, installation of surge protective devices (SPD) is a must. ABB has a long history of engineering and manufacturing quality surge protective devices. This brochure will provide all the information needed to select the proper products to begin protecting any facility or operation. ABB’s family of surge protective devices include the following: • OVR NE12 enclosed SPD for service entrance locations • OVR DIN rail AC SPD for equipment protection • OVR PV DIN rail DC SPD for photovoltaic installations • OVR DIN rail data line SPD for sensitive communications networks General information Introduction |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |