| 数据搜索系统,热门电子元器件搜索 |
|
SC2.2 数据表(PDF) 2 Page - Lapp. |
|
|
|||||||||||||||||||||||||||||
SC2.2 数据表(HTML) 2 Page - Lapp. |
|
2 / 4 page ![]() PRODUCT INFORMATION MULTI-STANDARD SC 2.2 Norm references / Approvals Multi-standard cables have conductor strands with nominal sizes in mm² or AWG/kcmil. The master size is mentioned in the table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related secondary size the cross-section of the conductor mostly works out to be greater than the specified nominal value. Cable type certifications: <HAR> H07V2-K acc. EN 50525-2-31, UL AWM style 10269 (by UL acc. UL standard UL 758, U.I. Lapp GmbH's UL AWM file number: E63634), (UL) MTW (by UL acc. UL standard UL 1063, U.I. Lapp GmbH's (UL) MTW file number: E198296), CSA TEW (by CSA acc. CSA standard CSA C22.2 No. 127, CSA class 5835-01) Product Make-up Fine-wire strand made of tinned-copper wires Special PVC-based core insulation Technical Data Classification: ETIM 5.0 Class-ID: EC000993 ETIM 5.0 Class-Description: Single core cable Conductor stranding: Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5 Minimum bending radius: OD ≤ 8 mm: 4 x OD*/2 x OD**; 8 < OD ≤ 12 mm: 5 x OD*/3 x OD**; OD > 12 mm: 6 x OD*/4 x OD** Nominal voltage: HAR / IEC: U0/U: 450/750 V; UL (AWM): U: 1000 V; UL (MTW): U: 600 V; CSA (TEW): U: 600 V Temperature range: Fixed installation: HAR/IEC: -40°C to +90°C; UL (AWM): -40°C to +105°C; UL (MTW): -40°C to +90°C; CSA (TEW): -40°C to +105°C Note Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request. Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges. Packaging size: Coil ≤ 30 kg, otherwise drum Photographs are not to scale and do not represent detailed images of the respective products. * Prices are net prices without VAT and surcharges. Sale to business customers. Non-harmonsided, nominal cross-sections: 0.5 mm², 0.75 mm², 1 mm², 16 mm², 50 mm², 70 mm², 95 mm², 120 mm² *for conventional use, **for careful bending; "OD" = outer diameter The outer diameters stated in the part number table are maximum values. Last Update (13.01.2017) 2 / 4 ©2017 Lapp Group - Technical changes reserved Product Management www.lappkabel.de You can find the current technical data in the corresponding data sheet. PN 0456 / 02_03.16 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |