6 / 8 page ![]() Specifications - EL-R Series EL-R MODEL RANGE Voltage/Current Levels EL301R 0 to >30V; 0 to >1A (30W nominal power) EL183R 0 to >18V; 0 to >3.3A (60W nominal power) EL302R 0 to >30V; 0 to >2A (60W nominal power) EL561R 0 to >56V; 0 to >1.1A (60W nominal power) EL155R 0 to >15V; 0 to >5A (75W nominal power) EL303R 0 to >30V; 0 to >3A (90W nominal power) EL302RD 2 x (0 to >30V; 0 to >2A) (120W nominal power) EL302RT 2 x (0 to >30V; 0 to >2A) (130W nominal power) plus 1.5 to 5.0V @ 2A OUTPUT SPECIFICATIONS Output Setting & Control Voltage Setting: By coarse and fine controls. Current Setting: By single logarithmic control. Output Mode: Constant voltage or constant current with automatic cross-over. CC indicator lit in constant current mode. Output Switch: Electronic, non isolating. Preset voltage and current limit displayed when Output is off. On state indicated by LED. Output Performance Ripple & Noise: Typically <1mV rms, (CV mode, 20MHz bandwidth). Load Regulation: <0·01% of maximum output for a 90% load change (using remote sense). Line Regulation: <0·01% of maximum output for 10% line change. Transient Response: <50µs to within 50mV of setting for a 5% to 95% load change. Temp. Coefficient: Voltage: typically <100ppm/°C. Output Protection Output Protection: Output will withstand forward voltages of up to 20V above rated output voltage. Reverse protection by diode clamp for currents to 3A. Output Connections Output Terminals: Universal 4mm safety binding posts on 19mm (0·75”) spacing. Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires. Remote Sense Sense Selection: Voltage sensing is selected as Local or Remote by front panel switch. Sense Terminals: Sprung loaded screw-less terminals. METER SPECIFICATIONS Display Type: Dual 4-digit meters, 14mm (0·56”) LED. Voltage Meter Resolution: 10mV Accuracy: 0·3% of reading ± 3 digits Current Meter Resolution: 1mA Accuracy: 0·5% of reading ± 3 digits AUXILIARY OUTPUT (EL302RT only) Voltage: Variable <1.5V to >5V by front panel control. Meter accuracy: 0.3% ± 4 digits. Current limit: 2A minimum. Load regulation: <3% for 90% load change. Line regulation: <0.2% for 10% line voltage change. Ripple & Noise Typically <5mVrms, <15mVpk-pk (20MHz bandwidth): Output Protection: Output will withstand up to 7V forward voltage. Diode clamp reverse protection for currents up to 3A. Output Terminals: Universal 4mm safety binding posts on 19mm (0·75”) spacing. Status Indication: UNREG lamp. GENERAL SPECIFICATIONS Input AC Input: 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II VA Ratings: EL301R - 85 VA; EL302R, EL302P, EL183R, EL561R - 160VA; EL155R, EL303R - 250VA; EL302RD, EL302RT - 320VA Temperature & Environmental Operating Range: +5ºC to +40ºC, 20% to 80% RH Storage Range: -40ºC to + 70ºC Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2. Cooling: Silent fan-less convection cooling. Safety & EMC Safety: Complies with EN61010-1 EMC: Complies with EN61326 Physical Size: Single output models - 140x160x295 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD). Weight: EL301R - 3.4kg; EL302R, EL302P, EL183R, EL561R - 4.4kg: EL155R, EL303R - 5.0kg; EL302RD, EL302RT - 7.5kg. Accuracy specifications apply for the temperature range 18°C to 28°C after 1 hour warm-up. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. EX752M - higher voltage multi-mode dual Output voltages up to 150V The EX752M is a dual output 300 watt PSU with Multi-Mode capability. This enables it to operate as a dual power supply with two independent and isolated outputs, or as a single power supply of double the power. As a dual, each output provides 0 to 75V at 0 to 2A (mode A). As a single, the output can be selected as either 0 to 75V at 0 to 4A (mode B) or 0 to 150V at 0 to 2A (mode C). In single modes, the unused half of the unit becomes completely inoperative and its displays are blanked. EX355P/EX355P-USB: operation via RS-232 or USB The EX355P is a digitally controlled version of the EX355 with an isolated RS-232 interface. It offers a low-cost solution for a basic programmable PSU and will be sufficient for many applications where the sophistication and complexity of GPIB is not needed. A simple command set allows remote control of voltage, current and output enable together with read-back of metering values and operational status. Local control is via three rotary encoders providing rapid and accurate setting of voltage and current during bench use. The EX355P-USB has similar functionality but is controlled via a USB interface. EX752M, EX355P |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |