21 / 52 page ![]() RPM-Based Fan Controller with HW Thermal Shutdown Datasheet SMSC EMC2102 21 Revision 1.95 (10-19-06) DATASHEET 5.2 Fan Control Modes of Operation The EMC2102 has two modes of operation for the High Side Fan Driver. They are: 1. Manual Mode - in this mode of operation, the user directly controls the fan drive setting. Updating the Fan Driver Setting Register (see Section 6.12) will instantly update the fan drive. The Manual Mode is enabled by clearing the EN bit in the Fan Configuration Register (see Section 6.13). Whenever the Manual Mode is enabled the current drive will be changed to what was last written into the Fan Driver Setting Register. Setting the drive value to 00h will disable the High Side Fan Driver for lower power operation. 2. Using RPM based Fan Control Algorithm - in this mode of operation, the user determines a target TACH count and the drive setting is automatically updated to achieve this target speed. The algorithm uses the Spin Up Routine and has user definable ramp rate controls. 5.3 RPM based Fan Control Algorithm The EMC2102 includes a RPM based Fan Control Algorithm that controls an integrated linear High Side Fan Driver. This fan control algorithm automatically approaches and maintains the system’s desired fan speed to an accuracy directly proportional to the accuracy of the clock source. Figure 5.2 shows a simple flow diagram of the RPM based Fan Control Algorithm operation. The desired TACH count is set by the user inputting the desired number of 32.768KHz cycles that occur per fan revolution. The user may change the target count at any time. The user may also set the target count to FFh in order to disable the fan driver for lower current operation. For example, if a desired RPM rate for a 2-pole fan is 3000RPMs, then the user would input the hexidecimal equivalent of 655 (29h in the TACH Target Register). This number represents the number of 32.768KHz cycles that would occur during the time it takes the fan to complete a single revolution when it is spinning at 3000RPMs (see Equation [3] in Section 6.19). Table 5.1 Fan Controls Active for Operating Mode MANUAL MODE ALGORITHM Fan Driver Setting (read / write) Fan Driver Setting (read only) EDGES[1:0] EDGES[1:0] (Fan Configuration) - UPDATE[2:0] (Fan Configuration) - LEVEL (Spin Up Configuration) - SPINUP_TIME[1:0] (Spin Up Configuration) - Fan Step - Fan Minimum Drive Valid TACH Count Valid TACH Count - TACH Target TACH Reading TACH Reading |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |