39 / 128 page ![]() November 25, 2003 Am70PDL127BDH/Am70PDL129BDH 37 AD VAN C E INFORM ATION ences between the Persistent Sector Protection and the Password Sector Protection Mode: ■ When the device is first powered on, or comes out of a reset cycle, the PPB Lock bit set to the locked state, rather than cleared to the unlocked state. ■ The only means to clear the PPB Lock bit is by writ- ing a unique 64-bit Password to the device. The Password Sector Protection method is otherwise identical to the Persistent Sector Protection method. A 64-bit password is the only additional tool utilized in this method. Once the Password Mode Locking Bit is set, the pass- word is permanently set with no means to read, pro- gram, or erase it. The password is used to clear the PPB Lock bit. The Password Unlock command must be written to the flash, along with a password. The flash device internally compares the given password with the pre-programmed password. If they match, the PPB Lock bit is cleared, and the PPBs can be altered. If they do not match, the flash device does nothing. There is a built-in 2 µs delay for each “password check.” This delay is intended to thwart any efforts to run a program that tries all possible combinations in order to crack the password. Password and Password Mode Locking Bit In order to select the Password sector protection scheme, the customer must first program the pass- word. The password may be correlated to the unique Electronic Serial Number (ESN) of the particular flash device. Each ESN is different for every flash device; therefore each password should be different for every flash device. While programming in the password re- gion, the customer may perform Password Verify oper- ations. Once the desired password is programmed in, the customer must then set the Password Mode Locking Bit. This operation achieves two objectives: 1. Permanently sets the device to operate using the Password Protection Mode. It is not possible to re- verse this function. 2. Disables all further commands to the password re- gion. All program, and read operations are ignored. Both of these objectives are important, and if not care- fully considered, may lead to unrecoverable errors. The user must be sure that the Password Protection method is desired when setting the Password Mode Locking Bit. More importantly, the user must be sure that the password is correct when the Password Mode Locking Bit is set. Due to the fact that read operations are disabled, there is no means to verify what the password is afterwards. If the password is lost after setting the Password Mode Locking Bit, there will be no way to clear the PPB Lock bit. The Password Mode Locking Bit, once set, prevents reading the 64-bit password on the DQ bus and further password programming. The Password Mode Locking Bit is not erasable. Once Password Mode Locking Bit is programmed, the Persistent Sector Protection Lock- ing Bit is disabled from programming, guaranteeing that no changes to the protection scheme are allowed. 64-bit Password The 64-bit Password is located in its own memory space and is accessible through the use of the Pass- word Program and Verify commands (see “Password Verify Command”). The password function works in conjunction with the Password Mode Locking Bit, which when set, prevents the Password Verify com- mand from reading the contents of the password on the pins of the device. Write Protect (WP#) The Write Protect feature provides a hardware method of protecting sectors 0, 1, 268, and 269 in PDL 127 or in SA1-133, SA1-134, SA2-0, SA2-1 in PDL 129 with- out using V ID. This function is provided by the WP# pin and overrides the previously discussed High Voltage Sector Protection method. If the system asserts V IL on the WP#/ACC pin, the de- vice disables program and erase functions in the two outermost 4 Kword sectors on both ends of the flash array independent of whether it was previously pro- tected or unprotected. If the system asserts V IH on the WP#/ACC pin, the de- vice reverts to whether sectors 0, 1, 268, and 269 in PDL 127 or in SA1-133, SA1-134, SA2-0, SA2-1 in PDL 129 were last set to be protected or unprotected. That is, sector protection or unprotection for these sec- tors depends on whether they were last protected or unprotected using the method described in High Volt- age Sector Protection. Note that the WP#/ACC pin must not be left floating or unconnected; inconsistent behavior of the device may result. Persistent Protection Bit Lock The Persistent Protection Bit (PPB) Lock is a volatile bit that reflects the state of the Password Mode Lock- ing Bit after power-up reset. If the Password Mode Lock Bit is also set after a hardware reset (RESET# asserted) or a power-up reset, the ONLY means for clearing the PPB Lock Bit in Password Protection Mode is to issue the Password Unlock command. Suc- cessful execution of the Password Unlock command clears the PPB Lock Bit, allowing for sector PPBs modifications. Asserting RESET#, taking the device through a power-on reset, or issuing the PPB Lock Bit Set command sets the PPB Lock Bit to a “1” when the Password Mode Lock Bit is not set. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |