| 数据搜索系统,热门电子元器件搜索 |
|
AS7421 数据表(PDF) 12 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS7421 数据表(HTML) 12 Page - OSRAM GmbH |
|
12 / 53 page ![]() Document Feedback AS7421 Electrical Characteristics Datasheet • PUBLIC DS000667 • v2-00 • 2022-Oct-13 52 │ 11 Figure 7: Optical Characteristics of AS7421, Integration Time = 65.5 ms (unless otherwise noted) Symbol Parameter Conditions Min Typ Max Unit FWHM Full width half maximum of filter (8) 10 nm λ s Peak Wavelength Separation 5 nm dark Dark ADC count value Ee = 0 μW/cm² AGAIN: 128x Integration time: 65.5 ms 5 counts Gain ratio Optical gain ratios, relative to 1x gain setting AGAIN: 1x 1 AGAIN: 2x 2 AGAIN: 4x 4 AGAIN: 8x 8 AGAIN: 16x 16 AGAIN: 32x 32 AGAIN: 64x 64 AGAIN: 128x 128 AGAIN: 256x 256 SNRSYSTEM Signal to noise ratio of optical system (1) (2) Range: 750 nm – 1050 nm 500 ImSR Intra-module spectral repeatability (1) (3) Range: 750 nm – 1050 nm 0.5 % IMSR Inter-module spectral repeatability (1) (4) Range: 750 nm – 1050 nm 5 % Wacc Wavelength accuracy (1) (7) 5 nm tint Integration time (5) 0.5 65.5 256 ms t64CH Measurement time for all 64 channel (6) 4 x tint ms f Field of view of single photo diode -10 10 deg (1) Parameter not tested in final test but guaranteed by design and validation. (2) Verified with raw spectral data collected with reflectance standard sample (RSS) with reflectance of 99% (white diffusive target). Average and standard deviation is calculated for each channel ( λ CH) for 10 measurements. SNRSYSTEM = µ(λCH) / σ(λ CH). (3) Verified with raw spectral data collected with reflectance standard sample (RSS, 10 measurements per channel) with reflectance of 99% (white diffusive target) and wavelength calibration standard zenith polymer (WCS, 100 measurements per channel). (4) Verified with raw spectral data collected with reflectance standard sample (RSS, 10 measurements per channel for 10 devices) with reflectance of 99% (white diffusive target) and wavelength calibration standard zenith polymer (WCS, 100 measurements per channel for 10 devices). (5) 65.5 ms integration time to achieve 16-bit count value (depending on amount of light reflected to sensor) (6) 4 integration cycles are done automatically to process all 64 channels. (7) Verified after full sensor calibration. Raw spectral data recorded for each channel with wavelength calibration standard zenith polymer (WCS, 10 measurements per channel). (8) Parameter verified with collimated light at 0° AOI (angle of incidence). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |