| 数据搜索系统,热门电子元器件搜索 |
|
AS6204 数据表(PDF) 26 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS6204 数据表(HTML) 26 Page - OSRAM GmbH |
|
26 / 37 page ![]() Document Feedback AS6204 Register Description Datasheet • PUBLIC DS000628 • v4-00 • 2021-Oct-18 36 │ 25 completed transmission. The master can terminate the data transfer by transmitting a Not- Acknowledge after the transmitted slave data or by invoking a START or a STOP condition on the bus. 6.3.8 Alert Function If the device is configured for an interrupt mode operation (IM=1), the ALERT output can be used as an alert signal. If the polarity bit is set to ‘0’ (POL=’0’), the alert condition bit is set to ‘0’ in case the temperature has exceeded the configured value in register THIGH. Accordingly, the alert condition bit is set to ‘1’ if the temperature has fallen below the configured value in register TLOW. If the polarity bit is set to ‘1’ (POL=’1’), the alert condition bit is inverted. The following table summarizes the status of the alert condition bit with different alert conditions and polarity configurations. Figure 27: Alert Condition Bit Polarity Bit Alert Condition Alert Condition Bit (AC-Bit) 0 T ≥ THIGH 0 0 T ≤ TLOW 1 1 T ≥ THIGH 1 1 T ≤ TLOW 0 6.3.9 High Speed Mode The bus operation is limited to 400 kHz unless the master device issues a high-speed command as the first byte after a START condition. This switches the bus to a high-speed operation, which allows data transfer frequencies up to 3.4 MHz. The slave does not acknowledge such a command but the input-filter time constants on the serial interface (SDA and SCL) are adapted to allow the higher transfer rate. The slave does not acknowledge such a command but the input-filter time constants on the serial interface (SDA and SCL) are adapted to allow the higher transfer rate. After a high-speed command, the master transmits the slave address in order to invoke a data transfer. The bus keeps operating at the higher operating frequency until the master issues a STOP condition on the serial bus. Upon the reception of the STOP condition by the slave, the input filters are switched to their initial time constants, which allow lower transfer rates only. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |