| 数据搜索系统,热门电子元器件搜索 |
|
DMR35-DCMA4-DC1-R 数据表(PDF) 5 Page - Murata Power Solutions Inc. |
|
|
|||||||||||||||||||||||||||||
DMR35-DCMA4-DC1-R 数据表(HTML) 5 Page - Murata Power Solutions Inc. |
|
5 / 8 page ![]() DMR35-DCxA.A01.D04 Page 5 of 8 DMR35-DCxA Series DMR35 DC Micro and Milli-ammeters www.murata-ps.com METER CONFIGURATION Meter Range Settings DMR35 meter configuration is controlled through a 5-position DIP switch (SW1-SW5) on the rear of the meter. The individual switches are labelled 1 through 5 on the unit, and the ON position of the switches is also labelled. These switches are used to select both the meter’s measurement range and the display intensity (brightness). Switches SW3 through SW5 select the meter’s measurement range, as shown in the table below. Note that for these five meter models, switch SW3 selects either unipolar (OFF) or bipolar (ON) measurement ranges. Switches SW4 and SW5 select the magnitude of the measurement range. Switch Setting DMR35 Model SW3 SW4 SW5 DIP switch -DCMA1 -DCMA2 -DCMA3 -DCMA4 -DCUA OFF OFF OFF 0-1 mA 0-15 mA 0-100 mA 0-300 mA 0-50 µA OFF OFF ON 0-3 mA 0-20 mA 0-150 mA 0-500 mA 0-100 µA OFF ON OFF 0-5 mA 0-25 mA 0-200 mA 0-750 mA 0-200 µA OFF ON ON 0-10 mA 0-50 mA 0-250 mA 0-1000 mA 0-500 µA ON OFF OFF ±1 mA ±15 mA ±100 mA ±300 mA ±50 µA ON OFF ON ±3 mA ±20 mA ±150 mA ±500 mA ±100 µA ON ON OFF ±5 mA ±25 mA ±200 mA ±750 mA ±200 µA ON ON ON ±10 mA ±50 mA ±250 mA ±1000 mA ±500 µA The meter behaves differently depending on whether bipolar or unipolar range setting is selected. When the meter is set to a bipolar range setting, it will display measurements over a +/- range, flashing the display to indicate overflow for input values greater than +RANGE, and flashing the display to indicate underflow for input values less than –RANGE. A zero-value measurement will illuminate a single center LED. Increasingly negative input values will illuminate the bargraph from center to the leftmost LED until all left-side LEDs are illuminated at negative full-scale, and increasingly positive input values will illuminate the bargraph from center to the rightmost LED until all right-side LEDs are illuminated at positive full-scale. When set to a unipolar range setting, the meter will display measurements over a positive only range. Negative input values will result in an underflow condition of a flashing zero reading. Positive input values exceeding the maximum range will result in a flashing overflow condition. The bargraph will indicate a measurement of zero or less by illuminating the leftmost LED, and increasingly positive input values will illuminate the bargraph to the rightmost LED until all LEDs are illuminated at positive full-scale. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |