| 数据搜索系统,热门电子元器件搜索 |
|
E5AX-PRRF 数据表(PDF) 5 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5AX-PRRF 数据表(HTML) 5 Page - Omron Electronics LLC |
|
5 / 14 page ![]() E5AX-P E5AX-P 5 sible settings for temperature sensors. Refer to temperature range charts under Ordering Information for further information. The scale displayed (%C or %F) is selected by the operating mode selector (SW201). Switch setting Temperature sensor code Temperature range %C %F 0 R 0 to 1,700 0 to 3,000 1 S 0 to 1,700 0 to 3,000 2 K –200 to 1,300 –300 to 2,300 3 J –100 to 850 –100 to 1,500 4 T –200 to 400 –300 to 700 5 E 0 to 600 0 to 1,100 6 JPt100 –99.9 to 450.0 –99.9 to 800.0 7 Pt100 –99.9 to 450.0 –99.9 to 800.0 8 L –100 to 850 –100 to 1,500 9 U –200 to 400 –300 to 700 Operating Mode Selector (SW201, FUNCTION) This DIP switch selects the operation modes listed in the following table. Function Pin number Pin setting Control setting Not used.* 1 Leave turned OFF. Control output 2 ON Normal (cooling) OFF Reverse (heating) Input shift 3 ON Enabled OFF Disabled SP (set point)** 4 ON Enabled protection cancel OFF Disabled Display unit 5 ON %F OFF %C PID display 6 ON Enabled OFF Disabled *Always operate with pin 1 OFF. Operating with pin 1 ON could re- sult in malfunction. **SP protection cancel is effective only when SW101 (key protec- tion) is on. If the SP protection cancel is ON, key protection (SW101 ON) will not apply to the set point, i.e., you will be able to change the set point regardless of the setting of SW101. Alarm Mode Selector (SW205: ALM) Alarm mode selector is provided on all E5AX Temperature Controllers. Alarm modes, listed in the following table, can be selected using this switch. The switch is factory-set to position 2, i.e., the upper-limit alarm mode. Switch Mode (SW205) Alarm output Setting range setting Alarm operation Display When X is positive When X is negative 0 No alarm No display OFF --- 1 Upper- and lower-limit alarm )––( XX --- Thermocouple: 0% to 9,999%C/%F Platinum resistance thermometer: 0% to 999.9%C/%F 2 Upper-limit alarm –––( X X Thermocouple: –999% to 9,999%C/%F 3 Lower-limit alarm )––– X X Platinum resistance thermome- ter: –99.9% to 999.9%C/%F 4 Upper- and lower-limit range alarm –()– XX --- Thermocouple: 0% to 9,999%C/%F 5 Upper- and lower-limit alarm with standby se- quence 3––e XX --- Platinum resistance thermometer: 0% to 999.9%C/%F 6 Upper-limit alarm with standby sequence –––e X X Thermocouple: –999% to 9,999%C/%F 7 Lower-limit alarm with standby sequence 3––– X X Platinum resistance thermome- ter: –99.9% to 999.9%C/%F 8 Absolute-value alarm 1––( Y 0%C Y 0%C |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |