28 / 43 page ![]() Theory of operation STPM11/12/13/14 28/43 7.16 Mode signals The STPM1X includes four Mode signals. These signals change some of the operation of the STPM1X. The mode signals are not retained when the STPM1X supply is not available and then they are cleared when a POR occurs. The mode signals bit can be written using the normal writing procedure of the CFGI interface (see CFGI par. 7.17) – RD mode signal has been already described in par. 7.15 (configuring the STPM1X), but there is another implied function of the signal RD. When it is set, each sense amplifier is disconnected from corresponding anti-fuse element and this way, its 3V NMOS gate is protected from the high voltage of VOTP during permanent write operation. This means that as long as the VOTP voltage reads more than 3V, the signal RD should be set. – PUMP. When set, the PUMP mode signal transforms the MOP and MON pins to act as driving signals to implement a charge-pump DC-DC converter (see Figure 23.). This feature is useful in order to boost the VCC supply voltage of the STPM1X to generate the VOTP voltage (14V to 20V) needed to program the OTP anti-fuse elements. – CSEL (STPM13/14 only). Under normal operating conditions, if anti-tamper module is not activated (see PST configuration bits) the STPM1X will selects channel 1 as the source of current information. For debug or calibration purposes, it is possible to select channel 2 as source of current channel signal when the tamper module is disabled. This is done by setting CSEL mode bit. – WE (write Enable): This mode signal is used to permanently write to the OTP anti- fuse element. When this bit is not set, any writing to the configuration bit is recorded in the shadow latches. When this bit is set, the writing is recorded both in the shadow latch and in the OTP anti-fuse element. Table 15. Mode signals description Signal Name Bit Value Status Binary Command Hex Command PUMP 0 MOP and MON operate normally 0111000x 70 or 71 1 MOP and MON provide the driving signals to implement a charge-pump DC-DC converter 1111000x F0 or F1 CSEL 0 Current Channel 1 selected when tamper is disabled 0111100x 78 or 79 1 Channel 2 selected when tamper is disabled 1111100x F8 or F9 RD 0 The 56 Configuration bits originated by OTP anti-fuses 0111101x 7A or 7B 1 The 56 Configuration bits originated by shadow latches 1111101x FA or FB WE 0 Any writing in the configuration bits is recorded in the shadow latches 0111110x 7C or 7D 1 Any writing in the configuration bits is recorded both in the shadow latches and in the OTP anti-fuse elements 1111110x FC or FD |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |