| 数据搜索系统,热门电子元器件搜索 |
|
ADAU1961WBCPZ-R7 数据表(PDF) 23 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADAU1961WBCPZ-R7 数据表(HTML) 23 Page - Analog Devices |
|
23 / 73 page ![]() Data Sheet ADAU1961 STARTUP, INITIALIZATION, AND POWER analog.com Rev. B | 23 of 73 clock for reading and writing, do not attempt to access any other register. Any read or write is prohibited until the core clock enable bit (COREN) and the lock bit are both asserted. To program the PLL during initialization or reconfiguration of the clock setting, the following procedure must be followed: 1. Power down the PLL. 2. Reset the PLL control register. 3. Start the PLL. 4. Poll the lock bit. 5. Assert the core clock enable bit after the PLL lock is acquired. The PLL control register (Register R1, Address 0x4002) is a 48-bit register where all bits must be written with a single continuous write to the control port. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|