| 数据搜索系统,热门电子元器件搜索 |
|
TDF8541JS/N3.512 数据表(PDF) 10 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8541JS/N3.512 数据表(HTML) 10 Page - NXP Semiconductors |
|
10 / 54 page ![]() TDF8541 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved. Product data sheet Rev. 3 — 13 December 2011 10 of 54 NXP Semiconductors TDF8541 I2C-bus controlled 4 45 W power amplifier information, a POR occurs and the amplifier will not restart automatically. In I2C-bus mode, pin DIAG is pulled LOW to indicate a POR has occurred. In legacy mode, the amplifier restarts if pin STB remains HIGH. The device prevents amplifier plops during engine start. To prevent plops on the amplifier output caused by, for instance, a tuner regulator out of regulation, the voltage on pin STB can be made zero when an engine start is detected. Pin STB activates the fast mute, suppressing disturbances at the amplifier inputs. The built-in low battery voltage mute is the default, and in legacy mode is set to 5.5 V, but can also be set to 7.2 V via the I2C-bus. If the low battery voltage mute is set to 7.2 V, the amplifier activates fast mute (400 s) and enters the same cycle when the low V P mute was set to 5.5 V: discharge of the ACGND and SVR capacitors when the mute is completed and start-up when the supply voltage is above 8 V, when no POR has occurred. 7.3 Power-on reset and supply voltage spikes If in I2C-bus mode the supply voltage drops below 4.5 V, the content of the I2C-bus latches cannot be guaranteed and POR is activated at a typical VP level of 3.1 V. All latches are reset, the amplifier is switched off and pin DIAG is pulled LOW to indicate that a POR has occurred; see DB2[D7]. If IB1[D0] is set, the power-on flag is reset, pin DIAG is released and the amplifier starts. In legacy mode a supply voltage drop below 6 V switches off the amplifier. When the supply voltage is above 6 V the amplifier restarts if pin STB is still enabled. 7.4 Protection 7.4.1 Output protection and short-circuit protection If a short-circuit to ground, to VP or across the load occurs on one or more amplifier outputs, only the channel with the short will be switched off. The channel that has a short-circuit and the type of short-circuit can be read via the I2C-bus. If pin DIAG is enabled for load fault information (IB2[D4] = 0) pin DIAG is pulled LOW. The window protection prevents a restart of the channel with a short to ground or VP. With a short across the load the channel is switched on again after 15 ms to check if the short across the load is still present. If the short-circuit conditions are still present, the channel is Fig 6. Engine start protection amplifier re-start (depends on I2C-bus content) t (s) 001aam687 VP voltage (V) 14 10 7 6 3.5 UVP DC output voltage SVR voltage/DC input voltage t(start-Vo(off)) t(start-SVRoff) DC voltage output not filtered to ensure headroom SVR clamp voltage |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |