13 / 38 page ![]() TSL2562, TSL2563 LOW-VOLTAGE LIGHT-TO-DIGITAL CONVERTER TAOS066J − MAY 2007 13 The LUMENOLOGY r Company r r Copyright E 2007, TAOS Inc. www.taosinc.com Command Register The command register specifies the address of the target register for subsequent read and write operations. The Send Byte protocol is used to configure the COMMAND register. The command register contains eight bits as described in Table 3. The command register defaults to 00h at power on. Table 3. Command Register 6 75 4 ADDRESS 2 31 0 0 00 0 0 00 0 Reset Value: COMMAND CLEAR CMD WORD BLOCK FIELD BIT DESCRIPTION CMD 7 Select command register. Must write as 1. CLEAR 6 Interrupt clear. Clears any pending interrupt. This bit is a write-one-to-clear bit. It is self clearing. WORD 5 SMB Write/Read Word Protocol. 1 indicates that this SMB transaction is using either the SMB Write Word or Read Word protocol. BLOCK 4 Block Write/Read Protocol. 1 indicates that this transaction is using either the Block Write or the Block Read protocol. See Note below. ADDRESS 3:0 Register Address. This field selects the specific control or status register for following write and read commands according to Table 2. NOTE: An I2C block transaction will continue until the Master sends a stop condition. See Figure 14 and Figure 15. Unlike the I2C protocol, the SMBus read/write protocol requires a Byte Count. All four ADC Channel Data Registers (Ch through Fh) can be read simultaneously in a single SMBus transaction. This is the only 32-bit data block supported by the TSL2562 SMBus protocol. The BLOCK bit must be set to 1, and a read condition should be initiated with a COMMAND CODE of 9Bh. By using a COMMAND CODE of 9Bh during an SMBus Block Read Protocol, the TSL2562 device will automatically insert the appropriate Byte Count (Byte Count = 4) as illustrated in Figure 15. A write condition should not be used in conjunction with the Bh register. Control Register (0h) The CONTROL register contains two bits and is primarily used to power the TSL256x device up and down as shown in Table 4. Table 4. Control Register 6 75 4 POWER 2 31 0 0 00 0 0 00 0 Reset Value: CONTROL Resv Resv Resv Resv Resv Resv 0h FIELD BIT DESCRIPTION Resv 7:2 Reserved. Write as 0. POWER 1:0 Power up/power down. By writing a 03h to this register, the device is powered up. By writing a 00h to this register, the device is powered down. NOTE: If a value of 03h is written, the value returned during a read cycle will be 03h. This feature can be used to verify that the device is communicating properly. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |