2 / 2 page ![]() Input Voltage 18-72V DC Current <200 mA at 48V, <400 mA at 24V Battery Other Technical Data Dimensions (WxHxD) 483/584 x 44 x 274mm (19/23 x 1.75 x 10.8in.) Weight 4.94kg (11lbs.) Operating Temperature -40 to +65°C Storage Temperature -50 to +85°C Environment Storage: Transport: Operation: ETS 300 019-2-1 ETS 300 019-2-2 ETS 300 019-2-3 Alarms Battery Disconnection An optional feature that allows voltage controlled disconnection of batteries. Boost Charging Manual time controlled or automatic boost charging with adjustable time and voltage levels. Battery Test Automatic or manual testing of batteries up to four times per year with a 10 test memory. Variables include: test duration, end voltage, and amount of Ah’s to be discharged during test. Symmetry Measurement Optional tool that measures batteries for early detection of thermal runaway. Allows for separate measurements of up to 12 parallel battery branches, each divided into four blocks. Temperature Compensation Charging Allows continuous adjustment of output voltage according to battery temperature. Features include adjustable compensation factor and separate thresholds for high temperature alarms. PLD Optional feature that allows voltage or time controlled disconnection of non-essential load. Enhanced Battery Monitoring Monthly logging of essential battery parameters, including temperature, temp. hours, current, charging voltage, and symmetry voltage. Parameters are stored for 5 years. Interface Note: All specifications are subject to change without notification. Alarm History The last 40 events are saved and include a time and date stamp. Alarm Contacts 6 potential free change-over alarm contacts. Two open collector outputs for LVD operation. Alarms High System Voltage Low System Voltage Load/ Battery Disc. Mains Error Distribution Fuse Failure Battery Failure Module Failure Battery Temp. Alarm Symmetry Fault Battery Fuse Failure High Load Battery Fuse Disc. Urgent Module Failure Communication Failure Partial Load Disc. 1* 2* 4* 3* 4* 6* 5* 6* 6* 4* 5* 5* 4* 5* 4* * All alarms are indicated using an LED and displayed in the LCD. The numbers represent an example of alarm routing. Sixteen additional alarms are available and are configurable by changing the PCS EEPROM. Display 2x20 character LCD with backlight Internal Communication RS485 Data Bus for communication with a maximum of 128 rectifiers and 128 sub-controllers Internal Communication RS232 Serial interface for remote control from a PC with PowCom software Indications Green LED - Power ON Yellow LED - System warning message Red LED - System failure message Controls Four pushbutton controls Signal Collection Wide range of interface units with analog and digital input/outputs Software Site upgradeable by EEPROM flash Language Multiple language options www.power-one.com 11V0005-061 XCS V3.0 Controller XCS |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |