| 数据搜索系统,热门电子元器件搜索 |
|
AM22CWCKGCM2/1500B 数据表(PDF) 8 Page - Ashcroft, Inc. |
|
|
|||||||||||||||||||||||||||||
AM22CWCKGCM2/1500B 数据表(HTML) 8 Page - Ashcroft, Inc. |
|
8 / 9 page ![]() 8 of 9 ATE-2 Handheld Calibrator Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks ©2023 Ashcroft Inc. ate-2_calibrator_ds_RevG_01-31-23 ashcroft.com | 1.800.328.8258 | Contact Us Thermocouple Type Measurement Range (°C) Accuracy @ 25 °C) (Not Including Internal Reference Junction) Accuracy @ 25 °C (Including Internal Reference Junction Expressed as ±°C) Max Additional Error Due to Ambient Temperature Deviation from 25 °C (Expressed as Additional °C Deviation from 25 °C) J -151 to -210 1200 to -150 0.7 0.3 1.1 0.4 0.02 0.01 K -201 to -240 -101 to -200 -999 to -100 1.5 1.0 0.5 2.2 1.5 0.8 0.05 0.03 0.02 T -250 to -201 -200 to -101 -100 to 400 1.5 0.8 0.5 2.2 1.2 0.8 0.05 0.03 0.02 E -250 to -201 -200 to -101 -100 to 400 1.2 0.6 0.3 2.0 1.1 0.6 0.04 0.02 0.01 R & S -50 to 299 300 to 1768 3.4 1.2 3.6 1.3 0.10 0.04 B 100 to 199 200 to 499 500 to 999 1000 to 1820 14.0 5.0 3.0 1.2 14.0 5.0 3.0 1.2 0.44 0.16 0.08 0.04 N -250 to -226 -225 to -101 -100 to 1300 4.3 2.1 1.0 5.7 2.8 1.4 0.14 0.07 0.02 AMBIENT TEMPERATURE EFFECT: To calculate, multiply degrees deviation from 25 °C times the value listed in the far right column of the listed table. Only applied when using the internal reference junction, within the ambient window of 0-50 °C. TO CALCULATE TOTAL SYSTEM/MEASUREMENT ACCURACY: Accuracy = System Accuracy @ 25 °C + System Ambient Temperature Effect + Inaccuracy of Thermocouple Device SYSTEM ACCURACY (BASED ON DIRECT MILLIVOLT READING FROM THERMOCOUPLE): Includes the base unit and AM2-TC1 interface module. (Does not include inaccuracy due to the thermocouple device. Reference junction not applicable to direct millivolt readings.) Input Range of Module Accuracy @ 25 °C Max. Additional Error Due to Ambient Temperature Deviation from 25 °C (Expressed as Additional Millivolt Error Per Each °C Deviation from 25 °C) 10 to 100 mV ±0.01 to 100 mV .001 AM2-TC1 Thermocouple Temperature Modules |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |