| 数据搜索系统,热门电子元器件搜索 |
|
01693 数据表(PDF) 1 Page - Evolt |
01693 数据表(HTML) 1 Page - Evolt |
|
1 / 2 page ![]() LEDFIRE ADV Advanced Emergency Luminaire Non-maintained operation Soft-start charger to reduce building load Lowest energy consumption (avg. <0.25W) Fast emergency switch-over (<0.5s) for high-task areas Long life electronics 8 years design life at max. ambient High Quality Lithium battery (LiFePO4) and smart charger Standalone (SPU) Self test (AS2293/ IEC62034) DALI (IEC62386) Ektor wired monitored system ORDERING INFORMATION Order code 01693 Description Ledfire Advanced Emergency Luminaire DALI - D63 - W/F&P Driver Type DALI DT1 Emergency Item Code EV-LEDFIRE-ADV-DA MECHANICAL Body Material Polycarbonate Fitting Colour White Installation Type Recessed IP Rating IP44 Front Face Only ELECTRICAL Electrical Rating Class II Input Frequency 50 Hz Input voltage 230Vac In Australia the Input voltage is defined as 230Vac -6%/+10%. This effectively means that the voltage range of these products are 216Vac - 253Vac or 240V +6% Maximum Wattage 2.5 W Standby Power 0.25 W Standby power for non-maintained/switched maintained emergency devices is measured when the light is off and the charger is in standby mode. For maintained emergency devices, standby power is measured when the light is on and the charger is in standby mode. Typically, charging occurs for the first 16 hours after the device is powered or after a battery discharge. Working Temp Range 0 to 40 °C DRIVER Dimmable No Driver Included Yes Driver Type DALI DT1 Emergency Flex & Plug or Lead Length 1200 mm Wiring Type Re-wireable Flex & Plug (2 pin) EMERGENCY (EM SUFFIX) Replacement Battery Code 01302 Emergency Classification C0:D63, C90:D63 Emergency Control DALI Monitored (DT1) DALI Monitored ~ Supports Emergency test and monitoring over DALI (IEC62386) with full compliance to IEC62386-202. Emergency Duration 90 mins Emergency Lumen Output 330 lm Emergency Mode Non-Maintained Emergency Output Power 2100 mW COMPLIANCE Product Design Life 8 years The product design life relates to the total product life which includes LEDs, drivers and the enclosure. This is different to the LED lifetime which only refers to the economical lifetime of the LEDs at which time the lumen output has dropped below the L Value. The product design life is calculated at the maximum ambient or working temperature of the product and takes into account the Daily Use. Standards AS/NZS 60598.1 AS 60598.2.22 AS/NZS 61347.1 AS/NZS 61347.2.13 AS CISPR 15 AS/NZS 2293.3 1300 438 658 sales@evolt.com.au ektor.com.au © 2025 Evolt |
类似说明 - 01693 |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |