| 数据搜索系统,热门电子元器件搜索 |
|
E5CS-RKJX 数据表(PDF) 8 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CS-RKJX 数据表(HTML) 8 Page - Omron Electronics LLC |
|
8 / 12 page ![]() E5CS-X E5CS-X 8 Control Mode Selection ON/OFF Control Pin 1 of the internal DIP switch is factory-set to OFF, so the Temper- ature Controller performs ON/OFF control. Pin 1 OFF: Temperature Controller performs ON/OFF. Control output ON OFF Set temperature ON 16 5 4 3 2 PX ON Set pin 3 to ON when the Temperature Controller is used to control a cooling device, such as a freezer. Control output ON OFF Set temperature ON 16 5 4 3 2 PX ON PID Control Set pin 1 of the internal DIP switch to ON to make the Temperature Controller perform PID control. Follow the steps described below. Pin 1 ON: Temperature Controller performs PID control. ON 16 5 4 3 2 PX ON Determining Proportional Period Set pin 2 of the DIP switch to OFF to select a proportional period of 20 seconds. This is used when PID control is performed with the relay output of the Temperature Controller, or when using an exter- nal relay or contactor. Control output ON OFF 20 seconds ON 16 5 4 3 2 PX ON When a quick response is required, set pin 2 to ON to select a pro- portional period of 2 seconds. Even when a solid-state relay (SSR) is used, only set the 2-second proportional period where quick re- sponse is essential. With a relay control output, a proportional peri- od of 2 seconds will greatly reduce the service life of the relay. Control output ON OFF 2 seconds ON 16 5 4 3 2 PX ON Determining Control Output Operation If the Temperature Controller is used to control a heater, the control output can be set to perform reverse (inverted) operation. Set pin 3 of the control output mode selector switch to OFF. Reverse output ON OFF Set temperature ON 16 5 4 3 2 PX ON Conversely, if the Temperature Controller is used to control a cool- ing device such as a freezer, set pin 3 to ON. Normal output ON OFF Set temperature ON 16 5 4 3 2 PX ON When power is first turned ON, the proportional band is set to 3%. The optimum proportional band, however, is automatically calcu- lated and set within the range 3% to 20%, according to the changes in the temperature of the controlled system. This automatic adjust- ment of the proportional band is possible regardless of whether the controlled system is a heating or cooling system. When the power is turned OFF once, and then ON again, the control starts with the previous proportional band. A new proportional band, however, is automatically calculated and set. The calculation of the proportional band is not carried out, however, if the temperature of the controlled system changes at a rate faster than 7.5% of the full scale per 2 seconds (e.g., faster than 3.75 °C per second with a full scale of 100 °C). In this case, the previously calculated and set proportional band is used. The Temperature Controller is provided with an overshoot preven- tion function that suppresses the second overshoot and those that follow to a level less than the initial overshoot. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |