| 数据搜索系统,热门电子元器件搜索 |
|
KLNR30 数据表(PDF) 1 Page - Littelfuse |
|
|
|||||||||||||||||||||||||||||
KLNR30 数据表(HTML) 1 Page - Littelfuse |
|
1 / 2 page ![]() General Purpose Fuses 34 w w w . l i t t e l f u s e . c o m © 2005 Littelfuse • POWR-GARD™ Products Catalog KLNR/KLSR Class RK1 Fuses 250/600 VAC • Fast Acting • 1 – 600 Amperes Specifications Voltage Ratings: AC: 250 Volts (KLNR); 600 Volts (KLSR) DC: 125 Volts (1 – 600A KLNR); 250 Volts (1 – 30A KLSR); 300 Volts (35 – 600A KLSR). Interrupting Ratings: AC: 200,000 amperes rms symmetrical DC: 20,000 amperes Ampere Range: 1 – 600 amperes. Approvals: AC: Standard 248-12, Class RK1 UL Listed (File No: E81895) CSA Certified (File No: LR29862) DC: Littelfuse self-certified Ampere Ratings 1 10 40 100 250 2 12 45 110 300 3 15 50 125 350 4 20 60 150 400 5 25 70 175 450 6 30 80 200 500 8 35 90 225 600 Example part number (series & amperage): KLNR 200 Recommended Fuse Blocks LR250 series (for KLNR series fuses) LR600 series (for KLSR series fuses) Refer to the Blocks & Holders section of this catalog for additional information. KLNR/KLSR series RK1 fuses were the earliest type of current-limiting fuses developed. Their single-element, silver link design enables them to provide fast-acting overload and short-circuit protection. When used to protect inductive loads such as motors, solenoids, and transformers, KLNR/KLSR series fuses must be greatly oversized to prevent opening the fuses on harmless in-rush currents. In such applications, KLNR/ KLSR series fuses may only provide short-circuit protection. We recommend using POWR-PRO® LLNRK/LLSRK series Class RK1, dual-element, time-delay fuses in all new applications requiring the current-limiting ability of UL Class RK1 fuses. POWR-PRO LLNRK/ LLSRK series fuses are also recommended in existing applications where fast-acting RK1 or RK5 fuses have been opening on harmless system surges such as motor starting currents. Applications Resistance heaters Lighting circuits Non-inductive loads Molded case circuit breaker load centers and panelboards have increased interrupting ratings when series rated with Littelfuse KLNR/KLSR Class RK1 fuses. Refer to panelboard manufacturer’s literature for UL Listed combination of fuses and panelboards. Series ratings up to 200,000 amperes are available. Safety • 200,000 A.I.R. — Reliable interruption of all overcurrents up to 200,000 amperes. • Extremely current-limiting — Stops damaging short-circuit current faster than any mechanical protective device. • Fast-acting — Provides fast acting protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components. Longer Equipment Life • Current-limiting design reduces damage to equipment caused by heating and magnetic effects of short-circuit currents. Economical • Extremely current-limiting — often permits use of readily available, less costly equipment. • Used as input or output fuses for surge sensitive components such as variable speed drives and rectifiers, fast acting KLNR/KLSR fuses may prevent opening of expensive semiconductor fuses protecting individual components. Easy To Use • 200,000 A.I.R. rating minimizes need for short-circuit calculations. Dimensions • Refer to FLNR_ID for KLNR dimensions and FLSR_ID for KLSR dimensions. |
类似零件编号 - KLNR30 |
|
类似说明 - KLNR30 |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |