| 数据搜索系统,热门电子元器件搜索 |
|
009043-RAD14 数据表(PDF) 2 Page - Campbell Scientific United Kingdom |
|
|
|||||||||||||||||||||||||||||
009043-RAD14 数据表(HTML) 2 Page - Campbell Scientific United Kingdom |
|
2 / 2 page ![]() 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sales@campbellsci.co.uk | www.campbellsci.eu UK | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | SE ASIA | SOUTH AFRICA | SPAIN | USA © 2012 Campbell Scientific January 26, 2016 Specifications Ordering Information Temperature Probe (wiring configuration option required) 43347 - R.M. Young RTD NIST calibrated Temperature Probe in 4-wire configuration with 3 m standard cable. Other cable lengths available in 5 m increments e.g. 5, 10, 15 m. Calibration Option Optional 3-point calibration for the 43347 that provides ±0.1°C uncertainty (-50° to +50°C). Aspirated Shield 43502 - R.M. Young Aspirated Radiation Shield with AC power supply (1.8 m lead). Accessories 41003-5 - 10-plate Gill Naturally Aspirated Radiation Shield for applications that do not require fan-aspiration. It requires the #27251 split nut (see below). #27251 - Split nut plug that is required to mount the 43347 in the 41003-5 radiation shield. 009043 - RAD14 - 14 plate unaspirated radiation shield (14-25 mm dia). CM210 - Crossarm-to-Pole Bracket for attaching the 43502 onto two tower legs via a crossarm (one of the CM210s is included with the crossarm). 006903 - Suitable power cable for 43502 - specify required length in metres to reach AC power supply. 4WPB1K - 4 wire PRT module (1k) required if not using the current excitation outputs of a CR3000 or CR5000. 43347 RTD Temperature Probe Sensing Element: HY-CAL 1000 Ω Platinum RTD Temperature Range: ±50°C Accuracy: ±0.3°C at 0°C; ±0.1°C with NIST calibration Temperature Coefficient: 0.00375 Ω °C-1 Ambient Temperature (when housed in the 43502 shield): < 0.2°C RMS at 1000 W/m2 intensity Delta T (when housed in the 43502 shield): < 0.05°C RMS with 43502 shields equally exposed Overall Length: 17.8 cm (7 in) Stainless-Steel Sheath Diameter: 0.478 cm (0.188 in) Stainless-Steel Sheath Length: 6.12 cm (2.41 in) Total Probe Tip Length (stainless-steel sheath and moulded plastic): 10.08 cm (3.97 in) Weight: 0.54 kg (1.2 lb) 43502 Aspirated Radiation Shield Aspiration Rate: 5 to 11 m s-1 (16 to 36 fps) depending on sensor size Ambient Temperature: < 0.2°C (0.4°F) RMS at 1000 W/m2 intensity Delta T: < 0.05°C (0.1°F) RMS with like shields equally exposed Power Required: 12 to 14 Vdc at 500 mA for blower Mounting: V-block and U-bolt for vertical pipe with 2.5 cm to 5.0 cm (1.0 in. to 2.0 in.) diameter Length: 33 cm (13 in) Diameter: 20 cm (8 in) Weight: 1.1 kg (2.5 lb) For the 2 m measurement, the 43502 attaches to the legs of a UT20 or UT30 tower via a CM202, CM203, CM204, or CM206 crossarm. Two CM210s can be used to attach the crossarm to two tower legs. For the upper measurement, attach the 43502 to the top most mast of a UT930 tower (10 m measurement height). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |