27 / 86 page ![]() NOTES *1 Not available on shell size 6, CBD 46W4. *2 For additional information on accessories listed in steps 5, 6, 7 and 10, see Accessory Catalog. *3 When using G hood with CBD variants, use the extended height hood. See Accessories Catalog for extended G hood options. *4 For stainless steel dimpled male versions, contact Technical Sales. *5 Not available when using 2WK2, 3W3, 3WK3, 5W5, 8W8, instead use B, R, R3, R4, or R5. STEP 2 - CONNECTOR VARIANTS Shell Size 1 - 2WK2, 5W1 Shell Size 2 - 3W3, 3WK3, 7W2, 11W1 Shell Size 3 - 5W5, 9W4, 13W3, 17W2, 21W1 Shell Size 4 - 8W8, 13W6, 17W5, 21WA4, 25W3, 27W2 Shell Size 5 - 24W7, 36W4, 43W2, 47W1 Shell Size 6 - 46W4 STEP 1 - BASIC SERIES CBD – Professional/Industrial Quality, see Step 3. CBM – Military conformance with “closed entry” female signal con- tacts plated 0.000050 [1.27µ] gold over nickel plate. Choose “S” or “M” in Step 3. ORDERING INFORMATION - CODE NUMBERING SYSTEM Specify Complete Connector By Selecting An Option From Step 1 Through 8 STEP 3 - CONNECTOR GENDER F - Female - Professional Level - Open Entry Signal Contacts M - Male S - Female - Industrial / Military Level - PosiBand Closed Entry Signal Contacts 1 2 3 4 5 6 7 8 9 CBD 17W2 F 55 R7 N T2 X /AA 10 -14 *2 STEP 10 - SPECIAL OPTIONS FOR SPECIAL OPTIONS, SEE SPECIAL OPTIONS APPENDIX ON PAGE 81. CONTACT TECHNICAL SALES FOR ORDERING DETAILS OF THE FOLLOWING: Other Special Requirements. Straight / Right Angle Thermocouple PCB mount contacts. STEP 8 - SHELL OPTIONS 0 – Zinc Plated, with Chromate Seal. *4 S – Stainless Steel, passivated. X – Tin Plated. Z – Tin Plated and Dimpled (male connectors only). *2 STEP 5 - MOUNTING STYLE 0 – Mounting Hole, 0.120 [3.05] Ø 02 – Mounting Hole, 0.154 [3.91] Ø *5 B3 – Bracket, Mounting, Right Angle (90°) Metal with Cross Bar *5 B8 – Bracket, Mounting, Right Angle (90°) Plastic with Cross Bar F – Float Mounts, Universal P – Threaded Post, Brass, 0.250 [6.35] Length P2 – Threaded Post, Nylon, 0.250 [6.35] Length *5 R2 – Bracket, Mounting, Right Angle (90°) Metal, Swaged to Connector with 4-40 Thread Fixed Female Jackscrews with Cross Bar *5 R6 – Bracket, Mounting, Right Angle (90°) Metal, Swaged to Connector with 0.120 [3.05] Ø Mounting Hole with Cross Bar *5 R7 – Bracket, Mounting, Right Angle (90°) Metal, Swaged to Connector with 4-40 Threads with Cross Bar *5 R8 – Bracket, Mounting, Right Angle (90°) Metal, Swaged to Connector with 4-40 Locknut with Cross Bar S – Swaged Spacer, 4-40 Threads, 0.250 [6.35] Length, Spacer length changes to 0.265 [6.73] when used in conjunction with Code 93 contacts S2 – Swaged Spacer, 4-40 Threads, 0.125 [3.18] Length S5 – Swaged Locknut, 4-40 Threads S6 – Swaged Spacer with Push-on Fastener, 4-40 Threads, 0.250 [6.35] Length STEP 4 - CONTACT TERMINATION TYPE 0 – Connector ordered without size 8 power, shielded, air or high voltage removable contacts. See pages 60-88 for contact part numbers. Available on 2WK2, 3W3, 3WK3, 5W5 and 8W8. 2 – Fixed Solder Cup, Signal Contacts only. 3 – Solder, Straight Printed Board Mount with Signal Contacts, 0.170 [4.32] Tail Length. 35 – Solder, Straight Printed Board Mount with Signal and 0.078 [1.98] Ø Power Contacts, 0.170 [4.32] Tail Length. 36 – Solder, Straight Printed Board Mount with Signal and 0.094 [2.39] Ø Power Contacts, 0.170 [4.32] Tail Length. 37 – Solder, Straight Printed Board Mount with Signal and 0.125 [3.18] Ø Power Contacts, 0.170 [4.32] Tail Length. 5 – Solder, Right Angle (90°) Printed Board Mount with Signal Contacts only, 0.283 [7.19] Signal Contact Extension. 55 – Solder, Right Angle (90°) Printed Board Mount with Signal and 0.078 [1.98] Ø Power Contacts, 0.283 [7.19] Signal Contact Extension. 57 – Solder, Right Angle (90°) Printed Board Mount with Signal and 0.125 [3.18] Ø Power Contacts, 0.283 [7.19] Signal Contact Extension. 65 – Solder, Straight Printed Board Mount with Signal and Shielded Contacts MDS/FDS 4201D footprint, 0.170 [4.32] Signal Contact Tail Length. 7 – Solder, Metric System Right Angle (90°) Printed Board Mount with Signal Contacts only, 0.370 [9.40] Signal Contact Extension. 75 – Solder, Metric System Right Angle (90°) Printed Board Mount with Signal and 0.078 [1.98] Ø Power Contacts, 0.370 [9.40] Signal Contact Extension. 77 – Solder, Metric System Right Angle (90°) Printed Board Mount with Signal and 0.125 [3.18] Ø Power Contacts, 0.370 [9.40] Signal Contact Extension. *1 85 – Solder, Right Angle (90°) Printed Board Mount with Signal and Shielded Contacts MRT/FRT 4201D footprint, 0.283 [7.19] Signal Contact Extension. 93 – Size 20 Omega type compliant and Size 8 Bi-Spring type compliant, termination length 0.225 [5.72]. STEP STEP 9 - ENVIRONMENTAL COMPLIANCE OPTIONS /AA - RoHS Compliant *2 STEP 7 - LOCKING AND POLARIZING SYSTEMS 0 – None. V3 – Lock Tab, connector front panel mounted. V5 – Lock Tab, connector rear panel mounted. VL – Lock Lever, used with Hoods only. T – Fixed Female Jackscrews. T2 – Fixed Female Jackscrews. T6 – Fixed Male and Female Polarized Jackscrews. E – Rotating Male Jackscrews. E2 – Rotating Male Screw Locks. E3 – Rotating Male with Internal Hex for 3/32 Hex Drives E6 – Rotating Male and Female Polarized Jackscrews. NOTE: If compliance to environmental legislation is not required, this step will not be used. Example: CBD17W2F55R7NT2X EXAMPLE *2 STEP 6 - HOODS AND PUSH-ON FASTENERS 0 – None AN – Lightweight Aluminum Hood, nickel finish. AC – Lightweight Aluminum Hood, no finish. Z – Hood, Top or Side Opening, robust extended height, plastic and composite, with rotating male jackscrews, shell sizes 1 through 5 H – Hood, Top Opening, Metal, shell sizes 2 through 5 *3 G – Hood, EMI/RFI, Die Cast Zinc, shell sizes 1 through 6 N – Push-on Fastener, for Right Angle (90°) Mounting Brackets PROFESSIONAL, INDUSTRIAL AND MILITARY QUALITY THREE PERFORMANCE LEVELS FOR BEST COST/PERFORMANCE RATIO STANDARD DENSITY PCB MOUNT Combo-D D-Sub Positronic connectpositronic.com 21 DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |