3 / 12 page ![]() K8AK-AS 3 Specifications Weight Approx. 150 g Mounting Mounts to DIN Track Dimensions 22.5 × 90 × 100 mm (W×H×D) Allowable operating voltage range 85% to 110% of power supply voltage Allowable operating frequency range 50/60 Hz ±5 Hz Input frequency range K8AK-AS1 and K8AK-AS2: DC input or AC input (45 to 65 Hz) K8AK-AS3: AC input (45 to 65 Hz) Overload capacity K8AK-AS1 and K8AK-AS2: Continuous input at 120% of maximum input, 1 s at 150% K8AK-AS3: Continuous input at 120%, 30 s at 200%, and 1 s at 600% with an OMRON CT (K8AC-CT200L) Note: Overload capacity of primary side of CT. Repeat error Operating value ±0.5% full scale (at 25°C and 65% humidity, rated power supply voltage, DC or 50/60 Hz sine wave input) Operating time ±50 ms (at 25°C and 65% humidity, rated power supply voltage) Applicable standards Conforming standards EN 60947-5-1 Installation environment (pollution level 2, installation category III) EMC EN 60947-5-1 Safety standards UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA: C22.2 No.14, CCC: GB14048.5 Insulation resistance 20 M Ω min. Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and output terminals Between input terminals and output terminals Dielectric strength 2,000 VAC for one minute Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and output terminals Between input terminals and output terminals Noise immunity 1,500 V power supply terminal common/normal mode Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time Vibration resistance Frequency 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of protection Terminals: IP20 AS (I3 terminal) 0 10 10 60 50 40 30 20 515 Distance between products d [mm] I = 3 A I = 5 A I = 1 A I = 8 A K8AK No.3 K8AK No.2 K8AK No.1 K8AK No.4 K8AK No.5 DIN Track Distance between products: d Sample: K8AK-AS Applied voltage: 240 VAC Mounting distances: 0, 5, and 10 mm min. Test method ●Relationship of Mounting Distance between K8AK-AS Relays and Input Current (Reference Values) The following diagram shows the relationship between the mounting distances and the input current. If the relay is used with an input current that exceeds these values, the temperature of the K8AK may rise and shorten the life of the internal components. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |