8 / 12 page ![]() K8AK-AS 8 Checking Operation Overcurrents Gradually increase the input from 80% of the set value. The input will equal the operating value when the input exceeds the set value and the alarm indicator starts flashing. Operation can be checked by the relay outputs that will start after the operating time has passed. Undercurrent Gradually decrease the input from 120% of the setting and check the operation using the same method as for overcurrent. Example: Overcurrent Operating Mode, Normally Open Relay Drive, and an Operating Time of 5 s Connection Diagram How to Measure the Operating Time Overcurrent Change the input suddenly from 0% to 120% of the set value and measure the time until the Unit operates. Undercurrent Change the input suddenly from 120% to 0% of the set value and measure the time until the Unit operates. Monitoring Switch-mode Power Supplies Switch-mode Power Supplies cannot be monitored. In circuits with a capacitor input, including switch-mode power supplies, the input capacitor recharge current flows in pulse form as the load current. The K8AK-AS @ has a built-in filter as a countermeasure against high frequencies and cannot be used to remove pulse current. Can a motor with a rated current of 5 A be monitored using the K8AK? Are there any application precautions? The K8AK-AS1 and K8AK-AS2 cannot be used with motor loads. Use the K8AK-AS3 in combination with the K8AC- CT200L Current Transformer (CT). With motor loads, the startup current and stall current will cause a current of many times the rated current to flow. Refer to the following figure for information on the motor startup current. For a motor with a rating of 5 A, the startup current will be approximately 30 A. The startup current will exceed the overload capacity (rating: 150% for 1 s) of the K8AK-AS1 and K8AK-AS2 and result in failure of the Relay. To monitor the motor load, use the K8AK-AS3. (Overload capacity: 120% of rating for continuous load, 200% of rating for 30 s, and 600% of rating for 1 s). The K8AK-AS3 has a large input range. Pass the conductors multiple times through the special CT. Concept behind Passing Conductor through the CT When Using the K8AK-AS3 Example: Monitoring Overload of a Motor with a Rated Current of 5 A K8AK set value: Overcurrent detection, operating value setting: 25%, operating time: 0.1 s Startup lock timer: 0.1 to 30 s (Set the timer according to the duration of the startup current.) The setting range for the K8AK-AS3 is 10% to 100% of the rated current (i.e., 10 to 100 A). Pass the conductors through the CT five times so that at least 10 A of current flows. The input current to the K8AK will be 25 A (i.e., 5 A x 5 loops). If a startup current of six times the rated current is generated, it will be 150 A (i.e., 25 A x 6). The overload capacity for the K8AK-AS3 is 200% of the rating for 30 s. The Relay will not fail even if the startup current continues for 30 s, and it is possible to perform overload detection. Questions and Answers Q Set value Current input Alarm indicator Relay output Flashing Lit 5 s 100 VAC 100 VAC 30 Ω 0 to 10 A A A1 A2 ± C 100 V Variable autotransformer Input terminals Power supply Output Cycle counter 400 W (two in parallel) Q Q Q Several seconds to several tens of seconds Time from beginning of startup 100% 500% K8AC-CT200L Primary-side conductor To the K8AK-AS3 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |