14 / 58 page ![]() Bosch Sensortec | BMP384 Datasheet 14 | 58 Modifications reserved |Data subject not change without notice | Printed in Germany Document number: BST-BMP384-DS003-11 Revision_1.0_112020 3.4.3. IIR filter The environmental pressure is subject to many short-term changes, caused e.g. by slamming of a door or window, or wind blowing into the sensor. To suppress these disturbances in the output data without causing additional interface traffic and processor work load, the BMP384 features an internal IIR filter. It effectively reduces the bandwidth of the output signals7. The output of a next measurement step is filter using the following formula: ������������������������������������������������������������������������������������������������������������������������������������������������=������������������������������������������������������������������������������������������������������������������������������������������������_������������������������������������∗������������������������������������������������������������������������_������������������������������������������������������������������������������������������������������������������������������������+������������������������������������������������������������������������������������ ������������������������������������������������������������������������_������������������������������������������������������������������������������������������������������������������������������������+1 where data_filtered_old is the data coming from the previous acquisition, and data_ADC is the data coming from the ADC before IIR filtering. The IIR filter can be configured using setting iir_filter in “CONFIG” register (see 4.3.20). When writing to the register filter, the filter is reset. The next value will pass through the filter and be the initial memory value for the filter. IIR filter is reset if the temperature or pressure measurement is disabled (temp_en or press_en registers changed from ‘1’ to ‘0’) or when a transition from sleep mode to normal mode occurs. After enabling of pressure or temperature measurement, the filtering will start, thus the next incoming value will pass unfiltered and be the initial value of the IIR filter. The step response (e.g. response to in sudden change in height) of different filter settings is displayed in Figure 6. Figure 6: Step response at different IIR filter settings 3.4.4. Oversampling Noise depends on the oversampling and filter settings selected. The stated values were determined in a controlled pressure environment and are based on the average standard deviation of 32 consecutive measurement points taken at highest sampling rate (for details please refer to Table 22). This is required to exclude long term drifts from the noise measurement. 7 Since most pressure sensors do not sample continuously, filtering can suffer from signals with a frequency higher than the sampling rate of the sensor. E.g. environmental fluctuations caused by windows being opened and closed might have a frequency <5 Hz. Consequently, a sampling rate of ODR = 10 Hz is sufficient to obey the Nyquist theorem. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |