| 数据搜索系统,热门电子元器件搜索 |
|
RI-69 数据表(PDF) 2 Page - Comus International |
|
|
|||||||||||||||||||||||||||||
RI-69 数据表(HTML) 2 Page - Comus International |
|
2 / 3 page ![]() RI-69 Series Dry Reed Switch Technical Specifications Parameters Test Conditions Units RI-69 Operating Characteristics Operate Range AT 7-21 Release Range AT 3-16 Operate Time - including Bounce (typ.) ms 0.15 (25 AT) Bounce Time (typ.) ms 0.035 (25 AT) Release Time (max) μs 20 Resonant Frequency (typ.) Hz 11300 Electrical Characteristics Switched Power (max) W 20 Switched Voltage DC (max) V 200 Switched Voltage AC, RMS value (max) V 140 Switched Current DC (max) mA 1000 Switched Current AC, RMS value (max) mA 700 Carry Current DC (max) mA 1000 Breakdown Voltage (min) V 230 Contact Resistance (initial max.) mΩ 125 (25 AT) Contact Resistance (initial typ.) mΩ 95 (25 AT) Contact Capacitance (max) without test coil pF 0.25 Insulation Resistance (min) RH ≤ 45% MΩ 106 tinned; net mass is approximately 90mg; and can be mounted in any position. Shock The switches are tested in accordance with “IEC 68-2-27”, test Ea (peak acceleration 100 G, half sinewave; duration 11 ms). Such a shock will not cause an open switch (no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open. Vibration The switches are tested in accordance with “IEC 68-2-26”, test Fc (acceleration 10G; below cross-over-frequency 57 to 62 Hz; amplitude 0.75 mm; frequency range 10 to 2000 Hz; duration 90 minutes.) Such a vibration will not cause an open switch ( no magnetic field present) to close, nor a switch kept closed by an 80 AT coil to open. Mechanical Strength The robustness of the terminations is tested in accordance with “IEC 68-2-21”, test Ua1 (load 40 N). Operating and Storage Temperature Operating ambient temperature; min: -55°C; max: +75°C. Storage temperature; min: -55°; max: +125°C. Note: Temperature excursions up to 150°C may be permissible. For more information contact your nearest Comus Group sales office. Soldering The switch can withstand soldering heat in accordance with “IEC 68-2-20”, test Tb, method 1B: solder bath at 350 ± 10°C for 3.5 ± 0.5 s. Solderability is tested in accor- dance with “IEC 68-2-20” test Ta, method 3: solder globule temperature 235°C; ageing 1b: 4 hours steam. Welding The leads can be welded. Mounting The leads should not be bent closer than 1 mm to the glass-to-metal seals. Stress on the seals should be avoided Care must be taken to prevent stray magnetic fields from influencing the operating and measuring conditions. • As part of the company policy of continued product improvement, specifications may change without notice. Our sales office will be pleased to help you with the latest information on this product range and the details of our full design and manufacturing service. All products are supplied to our standard conditions of sale unless otherwise agreed in writing. USA Tel: +(1)973 777 6900 / Fax: +(1) 973 777 8405 ▪ Belgium Tel: + 32 (0)12 390400 Page 2 of 3 5 / 2015 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |