4 / 18 page ![]() 4 Specifications are subject to change without notice WM30 96 DS 240914 WM30 96 Relay outputs (M O R2) Physical outputs 2 (max. 1 module per instrument) Purpose For either alarm output or pulse output Type Relay, SPDT type AC 1-5A @ 250VAC; AC 15-1.5A @ 250VAC Configuration By means of the front key- pad Function The outputs can work as alarm outputs but also as pulse outputs, remote controlled outputs, or in any other combination. Alarms Up alarm and down alarm linked to the virtual alarms, other details see Virtual alarms Min. response time ≤200ms, filters excluded. Set-point on-time delay: “0 s”. Pulse Signal retransmission Total: +kWh, -kWh, +kvarh, -kvarh. Partial: +kWh, -kWh, +kvarh, -kvarh. Pulse type Programmable from 0.001 to 10.00 kWh/kvarh per pulse.The above listed variables can be connected to any output. Pulse duration ≥100ms <120msec (ON), ≥120ms (OFF), according to EN62052-31 Remote controlled outputs The activation of the outputs is managed through the serial communication port Insulation See “Insulation between inputs and outputs” table Static outputs (M O O2) Opto-Mos type Physical outputs 2 (max. 1 module per instrument) Purpose For either pulse output or alarm output Signal VON: 2.5VAC/DC/max.100mA VOFF: 42VDC max. Configuration By means of the front key- pad Function The outputs can work as alarm outputs but also as pulse outputs, remote controlled outputs, or in any other combination. Alarms Up alarm and down alarm linked to the virtual alarms, other details see Virtual alarms Min. response time ≤200ms, filters excluded. Set-point on-time delay: “0 s”. Pulse Signal retransmission Total: +kWh, -kWh, +kvarh, -kvarh. Partial: +kWh, -kWh, +kvarh, -kvarh. Pulse type Programmable from 0.001 to 10.00 kWh/kvarh per pulse.The above listed variables can be connected to any output. Pulse duration ≥100ms < 120msec (ON), ≥120ms (OFF), according to EN62052-31 Remote controlled outputs The activation of the outputs is managed through the serial communication port Insulation See “Insulation between inputs and outputs” table 20mA analogue outputs (M O A2) Number of outputs 2 per module (max. 1 module per instrument) Accuracy (@ 25°C ±5°C, R.H. ≤60%) ±0.2%FS Range 0 to 20mA Configuration By means of the front key- pad Signal retransmission The signal output can be connected to any instantaneous variable available in the table “List of the variables that can be connected to”. Scaling factor Programmable within the whole range of retransmission. Response time ≤400 ms typical (filter excluded) Ripple ≤1% (according to IEC 60688-1, EN 60688-1) Total temperature drift ≤500 ppm/°C Load ≤600Ω Insulation See “Insulation between inputs and outputs” table 10VDC analogue outputs (M O V2) Number of outputs 2 (max. 1 module per instrument) Accuracy (@ 25°C ±5°C, R.H. 60%) ±0.2%FS Range 0 to 10 VDC Configuration By means of the front key- pad Signal retransmission The signal output can be connected to any instantaneous variable available in the table “List of the variables that can be connected to”. Scaling factor Programmable within the whole range of retransmission; Response time ≤400 ms typical (filter excluded) Ripple ≤1% (according to IEC 60688, EN 60688) Total temperature drift ≤350 ppm/°C Load ≥10kΩ Insulation See “Insulation between inputs and outputs” table Output specifications |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |