15 / 24 page ![]() LTC4223-1/LTC4223-2 15 422312f APPLICATIONS INFORMATION Power-Good Monitor Internal circuitry monitors the output voltages, AUXOUT and 12VOUT. The power-good status is reported via their respective open drain outputs, ⎯A⎯U⎯X⎯P⎯G⎯O⎯O⎯D and ⎯1⎯2⎯P⎯G⎯O⎯O⎯D. Several conditions must be met before the power-good outputs assert low. 1. The monitored output should be above its power- good threshold and hysteresis. 2. The input supply is above undervoltage lockout. 3. ⎯E⎯N is low. 4. The associated ON pin is high. 5. Thermal shutdown is not activated. If any of the supply outputs falls below its power-good threshold for more than 20μs, the respective power-good output will be pulled high by the external pull-up resistor or internal 10μA pull-up. Resetting Faults (LTC4223-1) Any supply faults tripping the circuit breaker are latched and ⎯F⎯A⎯U⎯L⎯T asserts low. For the latched-off version (LTC4223-1), to reset a fault latch due to overcurrent or thermal shutdown on auxiliary supply, pull both AUXON and 12ON pins low together for at least 100μs, after which the ⎯F⎯A⎯U⎯L⎯T will go high. Toggling both the ON pins high together again initiates the debounce timing cycle, thereafter the auxiliary supply starts up first followed by 12V supply. To skip the debounce timing cycle, first pull only AUXON low then high for at least 50μs before toggling 12ON low then high. The fault latch clears on the falling edge of 12ON and the auxiliary supply powers up. Thereafter, the 12V supply powers up if 12ON pulls high. To reset a fault on the 12V supply and re-start the output, toggle only the 12ON pin low and then high again. Tog- gling the ⎯E⎯N pin high then low again or bringing the bias input, VCC below its UVLO threshold for more than 100μs will initiate the debounce timing cycle and reset all fault latches before power-up. Bringing AUXIN or 12VINbelowits undervoltage threshold will not reset the fault latches. For the auto-retry version (LTC4223-2), the latched fault will be cleared automatically after a cool-off timing cycle. Auto-Retry after a Fault (LTC4223-2) At time point 1 in Figure 8, if a fault latched-off the 3.3V auxiliary supply after power-up, a cool-off cycle begins. The TIMER capacitor charges up to 1.235V with a 10μA current and then discharges with a 2μA current to 0.2V at time point 3. This is followed by a debounce timing cycle whereby the fault latch is cleared, and ⎯F⎯A⎯U⎯L⎯T pulls high when TIMER reaches its threshold at time point 4. At the end of debounce cycle, the internal switch is allowed to turn on. If the output short persists, the auxiliary supply powers up into a short with active current limiting. At time point 7, the fault filter delay begins with TIMER ramping up with a 10μA current. If the TIMER times out at time point 8, ⎯F⎯A⎯U⎯L⎯T will be pulled low and a new cool-off cycle begins with TIMER ramping down with a 2μA current. The whole process repeats itself until the output-short is removed. In Figure 9, a fault latches off the 12V supply at time point 1; a cool-off cycle begins by discharging the TIMER ca- pacitor with 2μA current from 1.235V to 0.2V threshold. At time point 2 a new debounce timing cycle is initiated where the fault latch is cleared, and ⎯F⎯A⎯U⎯L⎯T pulls high when TIMER reaches its threshold at time point 3. At the end of the debounce cycle, the 12V GATE is allowed to start up. If the output short persists, the 12V supply powers up into a short with active current limiting. At time point 6, the fault filter delay begins with TIMER ramping up with a 200μA current. The TIMER times out at time point 7, ⎯F⎯A⎯U⎯L⎯T pulls low and a new cool-off cycle begins with TIMER ramping down with a 2μA current. The whole process repeats itself until the output-short is removed. The auto-retry duty cycle is given by: DutyCycle t tt t FILTER COOL DEBOUNCE FILT = ++ •% 100 E ER For example, if TIMER capacitor, CT = 0.1μF, the auto-retry duty cycle for auxiliary and 12V supply is 6.5% and 0.5% respectively. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |