24 / 44 page ![]() LM63 SNAS190E – SEPTEMBER 2002 – REVISED MAY 2013 www.ti.com Table 6. Configuration Register ADDRESS READ/ POR BITS NAME DESCRIPTION HEX WRITE VALUE 03 (09)HEX CONFIGURATION REGISTER When this bit is a 0, ALERT interrupts are enabled. ALERT 7 0 When this bit is set to a 1, ALERT interrupts are masked, and the Mask ALERT pin is always in a high-impedance (open) state. When this bit is a 0, the LM63 is in operational mode, converting, comparing, and updating the PWM output continuously. When this bit is a 1, the LM63 enters a low-power standby mode. 6 0 STANDBY In STANDBY, continuous conversions are stopped, but a conversion/comparison cycle may be initiated by writing any value to register 0x0F. Operation of the PWM output in STANDBY depends on the setting of bit 5 in this register. When this bit is a 0, the LM63’s PWM output continues to output the PWM Disable current fan control signal while in STANDBY. 5 0 in STANDBY When this bit is a 1, the PWM output is disabled (as defined by the PWM polarity bit) while in STANDBY. 4:3 00 These bits are unused and always set to 0. When this bit is a 0, the ALERT/Tach pin is an open drain ALERT 03 (09) R/W output. ALERT/Tach When this bit is a 1, the ALERT/Tach pin is a high-impedance 2 0 Select Tachometer input. Note that if this bit is set, the function of the ALERT/Tach pin must be Tach input, so an external ALERT condition will not occur. The T_CRIT limit for the remote diode is nominally 85°C. This value can be changed once after power-up by first setting this bit to a 1, T_CRIT Limit 1 0 then programming a new T_CRIT value into the Remote Diode Override T_CRIT Limit (register 0x19). The T_CRIT value can not be changed again except by cycling power to the LM63. 0: an ALERT will be generated if any Remote Diode conversion result is above the Remote High Set Point or below the Remote Low RDTS Fault Setpoint. 0 0 Queue 1: an ALERT will be generated only if three consecutive Remote Diode conversions are above the Remote High Set Point or below the Remote Low Setpoint. 24 Submit Documentation Feedback Copyright © 2002–2013, Texas Instruments Incorporated Product Folder Links: LM63 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |