| 数据搜索系统,热门电子元器件搜索 |
|
TZ4ST-R4S 数据表(PDF) 8 Page - Autonics Corporation |
|
|
|||||||||||||||||||||||||||||
TZ4ST-R4S 数据表(HTML) 8 Page - Autonics Corporation |
|
8 / 16 page ![]() H-79 (A) Photo electric sensor (B) Fiber optic sensor (C) Door/Area sensor (D) Proximity sensor (E) Pressure sensor (F) Rotary encoder (G) Connector/ Socket (H) Temp. controller (I) SSR/ Power controller (J) Counter (K) Timer (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device (T) Software (U) Other Dual PID Auto Tuning Control Parameter 2 group Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default IN-T KCaH AL-T AL-A PIDT PIdS H-SC 1300 EU-1 AL-1 AtT TVN1 O-FT HEAT L-SC -100 EU-2 AL-2 RAMP OFF UNIT ?C LOC OFF ※Press ( ) key and the right digit of SV display part flashes. Press ( ) or ( ) key and move to the desired digit. Press ( ), ( ) keys to change SV and press MD key to complete the set. Press MD key again and it moves to next parameter. ※After completing setting at each parameter, press MD key for 3 sec. and it returns to RUN mode. ※If no key touched for 60sec., it will return to RUN mode automatically. ※1: It may not be displayed by input type switch. ※2: This is displayed only for model with High/Low-limit of transmission output. Factory defaults(Parameter 2 group) IN-T Input type: Select from 19 type L-SC Set scaling low limit (include analog output) EU-1 Event 1: Select from 9 type DOT Select decimal point position for Analog input EU-2 Event 2: Select from 9 type FS-H Set the high-limit when retransmission output is applied. (20mA) AL-T Alarm type: Select from 4 type FS-L Set the low-limit when retransmission output is applied. (4mA) AtT Auto-tuning: Selectable TUN1 or TUN2. RAMP Able to set ON and OFF of Ramp function. PIDT PID: Selectable PIDF or PIDS. BPS Set communication speed O-FT Selectable heat-function or cool-function ADRS Set communication address(01 to 99) UNIT Temperature unit: ℃ or ℉ LOC The data cannot be changed when the lock key is ON H-SC Set scaling high limit (include analog output) If pressing MD + key for 3sec. at once in RUN state, it will go to parameter 2 group. Input type Event 1 mode Alarm type PID type Control operating type Temperature unit ※2 ※2 Input type Lock ※2 Event 2 mode Auto-tuning type Scaling high limit Transmission output low limit Communication address Communication speed Ramp function Transmission output high limit Scaling low limit ※1 Decimal point ※1 IN-T KCaH JIcH JIcL R PR ECrL ECrH TCcH TCcL S PR NN U TT JPtH KCaL JPtL DPtH DPtL A--1 A--2 A--3 EU-1 LBA SBA AL-0 AL-1 AL-2 AL-4 AL-3 AL-5 AL-6 EU-2 LBA SBA AL-0 AL-1 AL-2 AL-4 AL-3 AL-5 AL-6 AL-T AL-A AL-B AL-C AL-D IN-T AtT TVN1 TVN2 LOC OFF ON PIDT PIdS PIdF ADRS 01 O-FT HEAT COOL BPS 2400 4800 9600 UNIT ?C ?F H-SC 1300 RAMP OFF ON L-SC -100 FS-L -100 FS-H 1300 DOT 0 )0 )00 )000 MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD Run mode MD + 3sec. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |