| 数据搜索系统,热门电子元器件搜索 |
|
TZ4ST-R4C 数据表(PDF) 7 Page - Autonics Corporation |
|
|
|||||||||||||||||||||||||||||
TZ4ST-R4C 数据表(HTML) 7 Page - Autonics Corporation |
|
7 / 16 page ![]() H-78 TZN/TZ Series Set alarm temperature in SV2. Set range: Within the rated using range of each sensor. Set alarm temperature in EV-1. Set range: Within the rated using range of each sensor. Set alarm temperature in EV-2. Set range: Within the rated using range of each sensor. If press MD key for 3sec., it will go to parameter 1 group. Set monitoring time of loop break alarm. Set range: 0 to 999 sec. Set interval between ON and OFF for alarm output. Set range: 1 to 100 ℃ (0.1 to 100.0℃) ※It is only displayed for temperature alarm output. Set proportional band. / Set range: 0.0 to 100.0%. ※If setting value P as 0.0, it will be ON/OFF control. Set integral time. / Set range: 0 to 3600 sec. ※If setting value I as 0 sec., this function will be OFF. ※It is not displayed when P is 0.0. (ON/OFF control) Set derivative time. / Set range: 0 to 3600 sec. ※If setting value D as 0 sec., this function will be OFF. ※It is not displayed when P is 0.0. (ON/OFF control) Set control period cycle. / Set range: 1 to 120 sec. ※In case of SSR output, this value should be small.(Ex: 2sec.) ※It is not displayed when P is 0.0. (ON/OFF control) Set hysteresis. / Set range: 1 to 100 ℃ (0.1 to 100.0℃) ※It is only displayed for ON/OFF control. Correct the error in input sensor. Set range: -49 to 50 ℃ (-50.0 to 50.0℃) Set manual reset value. / Set range: 0.0 to 100.0% ※It is only displayed for P control. Set ramp rising-time. / Set range: 1 to 99 min. ※It displayed only when selecting Ramp function in setting 2 group. Set ramp falling-time. / Set range: 1 to 99 min. ※It is displayed when selecting Ramp function at parameter 2 group. Cancel the lock function for OFF. This function is for locking the setting value.(available to operate AT Key) Select ON1, changing setting value in the parameter 1 group and AT key in the front panel cannot be changed. SV2 (Setting value 2) AL1 setting value AL2 setting value Loop break alarm Alarm hysteresis Proportional band Integral time Derivative time Control time Hysteresis Input correction Manual reset RAMP rising RAMP-up time RAMP falling RAMP-down time Lock Flow chart for parameter 1 group ※Press ( ) key and the right digit of SV display part flashes. Press ( ) or ( ) key and move to the desired digit. Press ( ), ( ) keys to change SV and press MD key to complete the set. Press MD key again and it moves to next parameter. ※After completing setting at each parameter, press MD key for 3 sec. and it returns to RUN mode. ※If no key touched for 60sec., it will return to RUN mode automatically. ※ This parameter [ AL1, AL2, LBA, I, D, T, HYS, REST, RAPU, RAPD ] might not be displayed depending on other parameter settings. Factory defaults(Parameter 1 group) Parameter Factory default Parameter Factory default Parameter Factory default Parameter Factory default SU-2 0 AHYS 2 T 20 RAPU 10 AL1 10 P #0 HYS 2 RAPD 10 AL2 10 I 0 IN-B 0 LOC OFF LBA 600 D 0 REST )0 Run mode MD MD MD MD MD MD MD MD MD MD MD MD MD MD MD AL1 10 I 0 LBA 999 T 20 RAPU 10 AL2 10 D 0 REST )0 AHYS 2 HYS 2 RAPD 10 ON ON1 SU-2 0 P #0 IN-B 0 LOC OFF MD 3sec. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |