| 数据搜索系统,热门电子元器件搜索 |
|
M58LR128GT 数据表(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M58LR128GT 数据表(HTML) 19 Page - STMicroelectronics |
|
19 / 84 page ![]() 19/84 M58LR128GT, M58LR128GB The segments are programmed one Word at a time. When shipped all bits in the segment are set to ‘1’. The user can only program the bits to ‘0’. Two Bus Write cycles are required to issue the Protection Register Program command. ■ The first bus cycle sets up the Protection Register Program command. ■ The second latches the address and data to be programmed to the Protection Register and starts the Program/Erase Controller. Read operations to the bank being programmed output the Status Register content after the pro- gram operation has started. Attempting to program a previously protected Pro- tection Register will result in a Status Register er- ror. The Protection Register Program cannot be sus- pended. Dual operations between the Parameter Bank and the Protection Register memory space are not allowed (see Table 15., Dual Operation Limitations for details). The two Protection Register Locks are used to protect the OTP segments from further modifica- tion. The protection of the OTP segments is not re- versible. Refer to Figure 5., Protection Register Memory Map, and Figure 5., Protection Register Memory Map, for details on the Lock bits. See APPENDIX C., Figure 26., Protection Regis- ter Program Flowchart and Pseudo Code, for a flowchart for using the Protection Register Pro- gram command. Set Configuration Register Command The Set Configuration Register command is used to write a new value to the Configuration Register. Two Bus Write cycles are required to issue the Set Configuration Register command. ■ The first cycle sets up the Set Configuration Register command and the address corresponding to the Configuration Register content. ■ The second cycle writes the Configuration Register data and the confirm command. The Configuration Register data must be written as an address during the bus write cycles, that is A0 = CR0, A1 = CR1, …, A15 = CR15. Addresses A16- A22 are ignored. Read operations output the array content after the Set Configuration Register command is issued. The Read Electronic Signature command is re- quired to read the updated contents of the Config- uration Register. Block Lock Command The Block Lock command is used to lock a block and prevent program or erase operations from changing the data in it. All blocks are locked after power-up or reset. Two Bus Write cycles are required to issue the Block Lock command. ■ The first bus cycle sets up the Block Lock command. ■ The second Bus Write cycle latches the block address and locks the block. The lock status can be monitored for each block using the Read Electronic Signature command. Table 16. shows the Lock Status after issuing a Block Lock command. Once set, the Block Lock bits remain set even after a hardware reset or power-down/power-up. They are cleared by a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation. See APPENDIX C., Figure 25., Locking Operations Flowchart and Pseudo Code, for a flowchart for using the Lock command. Block Unlock Command The Block Unlock command is used to unlock a block, allowing the block to be programmed or erased. Two Bus Write cycles are required to issue the Block Unlock command. ■ The first bus cycle sets up the Block Unlock command. ■ The second Bus Write cycle latches the block address and unlocks the block. The lock status can be monitored for each block using the Read Electronic Signature command. Table 16. shows the protection status after issuing a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation and APPENDIX C., Figure 25., Locking Operations Flowchart and Pseudo Code, for a flowchart for using the Block Unlock command. Block Lock-Down Command The Block Lock-Down command is used to lock- down a locked or unlocked block. A locked-down block cannot be programmed or erased. The lock status of a locked-down block cannot be changed when WP is low, VIL. When WP is high, VIH, the lock-down function is disabled and the locked blocks can be individually unlocked by the Block Unlock command. Two Bus Write cycles are required to issue the Block Lock-Down command. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |