| 数据搜索系统,热门电子元器件搜索 |
|
PRD 数据表(PDF) 1 Page - Tyco Electronics |
|
|
|||||||||||||||||||||||||||||
PRD 数据表(HTML) 1 Page - Tyco Electronics |
|
1 / 3 page ![]() 811 P&B Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 1-07) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. PRD series 10 to 50 Amp Heavy Duty AC or DC Power Relay File E22575 (Models With All Screw Terminals) File E22575 (All Others) File 15734 6 18 333 6 .86 1600 12 71 169 12 3.2 820 24 288 84 24 12.0 410 48 1150 41.7 120 290 85 110 6050 18.2 240 1200 43 220 Use 110V relay with approx. 480 4500 22 6,000 ohm 5W wire-wound resistor in series. DC Coils AC Coils (50-60Hz.) Nominal Resistance Nominal DC Nominal DC Resis. Nominal AC Volts In Ohms Current In Volts In Ohms Current In ±10%@ 25°C Milliamps ±15%@ 25°C Milliamps Features • Contact ratings to 50 amps. • Magnetic blowouts available for switching DC loads. • Arrangements to DPDT. • SPDT auxiliary switch available. • Replaces PR series. Contact Data @ 25°C Arrangements: Available to 2 Form C (DPDT). See ordering information. Ratings: See UL contact rating tables. Minimum Rating: 1A @ 12 VAC/VDC. Material: Silver and silver-cadmium oxide standard. Other materials available for special applications. Expected Life: 100,000 operations at rated loads @25°C. Specific exceptions are noted in ratings tables. Life increases at reduced loads or with appropriate arc suppression. Initial Dielectric Strength Initial Breakdown Voltage: 2,000V rms minimum between all elements and ground. (2,200V rms on 600V ratings.) Coil Data @ 25°C Voltage: From 6 to 220VDC, and 6 to 480VAC. Resistance: See coil data table. Nom. Power: DC coils: 2.0 watts @ 25°C.; AC coils: 9.8VA @ 25°C. Max Power: DC coils: 8.0 watts @ 25°C. Duty Cycle: Continuous. Initial Insulation Resistance: 100 megohms, minimum. Coil Data Operate Data @ +25°C Must-Operate Voltage: DC: 75% of nominal; AC: 85% of nominal. Environmental Data Temperature Range: AC: -55°C to +45°C.; DC: -55°C to +80°C. Mechanical Data Mounting: Two .187”(4.75mm) Dia. holes on 1.875” (47.63mm) centers. Termination: See ordering information tables for various options. Enclosure: Metal dust cover, 35D013, available. Order separately. Weight: 10 oz. (284g) approximately. Auxiliary Snap-Action Switch Arrangements: 1 Form C (SPDT). Rating: 5 amps at 120VAC, 60 Hz. @ 25°C. Material: Silver. Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. PRD-1, 3 or 5 Y 25 amps @ 277VAC 1 HP at 120VAC 2 HP at 250VAC 10 amps at 600VAC 7 amps at 50VDC Res. PRD-1, 3 or 5 G 30 amps at 277VAC Res. 1.5 HP at 120VAC 2HP at 250VAC 10 amp at 600VAC PRD-1, 3 or 5 F 50 amps at 240VAC Gen. Purp. (20,000 Ops.) 30 amps at 277VAC Res. 1.5 HP at 120VAC 2HP at 250VAC 10 amp at 600VAC PRD-7 or 11 Y 25 amps at 240VAC 20 amps at 277VAC 1 HP at 120VAC 2 HP at 250VAC 7 amps at 50VDC Res. 10 amps at 600VAC PRD-7 or 11 G 30 amps at 240VAC 20 amps at 277VAC 1.5 HP at 120VAC 2 HP at 250VAC 10 amps at 600VAC PRD-7 or 11 F 50 amps at 240VAC Gen. Purp. (20,000 Ops.) 30 amps at 240VAC 20 amps at 277VAC 1.5 HP at 120VAC 2 HP at 250VAC 10 amps at 600VAC PRD-3, 7 or 11 H or J 20 amp at 125VDC 1/3 HP at 125VDC PRD-1, 5, 7 or 11 N 25 amp at 250VAC 1 HP at 125VAC 2 HP at 250VAC Type Contact Code Contact Ratings UL/CSA Contact Ratings Models with Screws or Quick Connects as Main Terminals PRD-3AP4 P 50 amps at 277VAC, Gen. Purp. PRD-3DP4 30 amps at 277VAC, Ballast (6,000 Ops.) 15 amps at 277VAC, Tungsten (6,000 Ops.) 102LRA, 17FLA at 240VAC (30,000 Ops.) 120LRA, 20FLA at 120VAC (30,000 Ops.) 1.5 HP at 120VAC (30,000 Ops.) 3 HP at 240VAC (30,000 Ops.) Type Contact Code Contact Ratings UL Contact Ratings Models with Box Lugs as Main Terminals PRD-3AR4 R 60 amps at 28VDC Res. PRD-3DR4 30 amps at 125VDC Type Contact Code Contact Ratings DC Factory Contact Ratings Models with Box Lugs as Main Terminals Note: Any PRD relay deviating electrically or physically from the standard models in the table is not UL or CSA listed. All horsepower ratings are for single phase motors. Note: Any PRD relay deviating electrically or physically from the standard models in the table is not UL or CSA listed. All horsepower ratings are for single phase motors. Note: Any PRD relay deviating electrically or physically from the standard models in the table is not UL or CSA listed. All horsepower ratings are for single phase motors. Note: Any PRD relay deviating electrically or physically from the standard models in the table is not UL or CSA listed. All horsepower ratings are for single phase motors. |
类似零件编号 - PRD |
|
类似说明 - PRD |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |