89 / 93 page

IP178C/IP178C LF/IP178CH/IP178CH LF
Datasheet
3.3.3
RMII Timing
a. Receive Timing Requirements
89/93
June 21, 2007
Copyright © 2004, IC Plus Corp.
IP178Cx-DS-R12
Symbol
Description
Min.
Typ.
Max.
Unit
TClk
Clock period
-
20
-
ns
TsRxClk
RXDV, RXD to RMII_CLK_IN setup time
2
-
-
ns
ThRxClk
RXDV, RXD to RMII_CLK_IN hold time
0.5
-
-
ns
R M II_C LK _ IN
R X DV, RX D[1 :0 ]
T sRxClk
T hRxClk
T Clk
b. Transmit Timing
Symbol
Description
Min.
Typ.
Max.
Unit
TClk
Clock period
-
20
-
ns
TdTxClk
RMII_CLK_IN rising edge to TXEN, TXD
1
-
4
ns
TdTxClk
RMII_CLK_IN
TXEN, TXD[1:0]
TClk