| 数据搜索系统,热门电子元器件搜索 |
|
DAC8564 数据表(PDF) 30 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
DAC8564 数据表(HTML) 30 Page - Texas Instruments |
|
30 / 51 page ![]() V X OUT Amplifier Resistor String DAC Power-Down Circuitry Resistor Network DAC8165 SBAS409B – FEBRUARY 2008 – REVISED MARCH 2011 www.ti.com POWER-DOWN MODES DACs. However, for the three power-down modes, the supply current falls to 1.3 μA at 5.5V (0.5μA at The DAC8165 has two separate sets of power-down 3.6V). Not only does the supply current fall, but the commands. One set is for the DAC channels and the output stage also switches internally from the output other set is for the internal reference. For more of the amplifier to a resistor network of known values. information on powering down the reference, see the Enable/Disable Internal Reference section. The advantage of this switching is that the output impedance of the device is known while it is in DAC Power-Down Commands power-down mode. As described in Table 7, there are three different power-down options. VOUT can be The DAC8165 uses four modes of operation. These connected internally to GND through a 1k Ω resistor, a modes are accessed by setting three bits (PD2, PD1, 100k Ω resistor, or open circuited (High-Z). The output and PD0) in the shift register. Table 7 shows how to stage is shown in Figure 96. In other words, DB16, control the operating mode with data bits PD0 DB15, and DB14 = '111' represent a power-down (DB16), PD1 (DB15), and PD2 (DB14). condition with Hi-Z output impedance for a selected channel. '101' represents a power-down condition Table 7. DAC Operating Modes with 1k Ω output impedance, and '110' represents a PD0 PD1 PD2 power-down condition with 100k Ω output impedance. (DB16) (DB15) (DB14) DAC OPERATING MODES 0 X X Normal operation 1 0 1 Output typically 1k Ω to GND 1 1 0 Output typically 100k Ω to GND 1 1 1 Output high-impedance The DAC8165 treats the power-down condition as data; all the operational modes are still valid for power-down. It is possible to broadcast a power-down condition to all the DAC8165s in a system; it is also possible to simultaneously power-down a channel while updating data on other channels. Figure 96. Output Stage During Power-Down When the PD0 bit is set to '0', the device works normally with its typical current consumption of 1mA All analog channel circuitries are shut down when the at 5.5V with an input code = 8192. The reference power-down mode is exercised. However, the current is included with the operation of all four contents of the DAC register are unaffected when in power down. The time required to exit power-down is typically 2.5 μs for VDD = 5V, and 5μs for VDD = 3V. See the Typical Characteristics for more information. 30 Submit Documentation Feedback Copyright © 2008–2011, Texas Instruments Incorporated Product Folder Link(s): DAC8165 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |