ADS7828 数据表(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ADS7828 数据表(HTML) 21 Page - Texas Instruments |
|
21 / 36 page ![]() Sr A1 1 0 0 1 0 A0 R A 0 0 0 0 D11 D10 D9 D8 A D7 D6...D1 D0 N P S A1 1 0 0 1 1 0 A0 W A SD C2 C1 C0 PD0 X X A S A1 1 0 0 1 1 0 A0 W A X X X X X X X A P Wait until the required settling time is reached Internal Reference Turn-On Sequence Settled Internal Reference Settled Internal Reference Internal Reference Turn-On Settling Time Typical Read Sequence in F/S Mode (1) From Master to Slave A = Acknowledge (SDA low) N = Not acknowledge (SDA high) S = Start condition P = Stop condition Sr = Repeated Start condition W = 0 (write) R = 1 (read) From Slave to Master Command Byte Write-Addressing Byte Command Byte Write-Addressing Byte ADC Power-Down Mode ADC Sampling Mode ADC Converting Mode ADC Power-Down Mode (depending on power-down selection bits) Read-Addressing Byte 2 x (8 bits + ack/nack) See Note (2) NOTES: (1) Typical read sequences can be reused after the internal reference is settled. (2) To secure bus operation and loop back to the stage of write-addressing for next conversion, use Repeated Start. ADS7828-Q1 www.ti.com SBAS456B – DECEMBER 2008 – REVISED JANUARY 2016 Figure 20. Internal Reference Turn-On Sequence and Typical Read Sequence (F/S Mode Shown) When using an internal reference, there are three things that must be done: 1. To use the internal reference, the PD1 bit of Command Byte must always be set to logic 1 for each sample conversion that is issued by the sequence, as shown in Figure 18. 2. To achieve 12-bit accuracy conversion when using the internal reference, the internal reference settling time must be considered, as shown in the Internal VREF vs Turn-On Time Typical Characteristic plot. If the PD1 bit has been set to logic 0 while using the ADS7828, then the settling time must be reconsidered after PD1 is set to logic 1. In other words, whenever the internal reference is turned on after it has been turned off, the settling time must be long enough to get 12-bit accuracy conversion. 3. When the internal reference is off, it is not turned on until both the first Command Byte with PD1 = 1 is sent and then a Stop condition or repeated Start condition is issued. (The actual turn-on time occurs once the Stop or repeated Start condition is issued.) Any Command Byte with PD1 = 1 issued after the internal reference is turned on serves only to keep the internal reference on. Otherwise, the internal reference would be turned off by any Command Byte with PD1 = 0. The example in Figure 20 can be generalized for an HS mode conversion cycle by changing the timing of the conversion cycle. If using an external reference, PD1 must be set to 0, and the external reference must be settled. The typical sequence in Figure 18 or Figure 19 can then be used. Copyright © 2008–2016, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: ADS7828-Q1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |