| 数据搜索系统,热门电子元器件搜索 |
|
DFR0504 数据表(PDF) 2 Page - DFROBOT |
|
|
|||||||||||||||||||||||||||||
DFR0504 数据表(HTML) 2 Page - DFROBOT |
|
2 / 2 page ![]() Gravity: Analog Signal Isolator Interface The isolator is compatible with almost all analog output sensors of many types produced by DFRobot. Caution: 1.MCU should provide 5.0±0.1V power supply and it decides the finial output precision. 2.The module will consume a large current when it is working, you’d better to use an external power supply. 3.The MAX output current of SEN terminal is 170mA. 4.The GNDs of SEN and MCU are isolated, please DO NOT connect them together. 5.It will be a little warm when it is working. SPECIFICATION Operating Voltage: 5.0V Response Time: 4 seconds (Typ) Analog Error (both ends): <± 20mV (Typ) Interface Type: PH2.0-3P No load Current: 75mA Dimension: 42 * 32mm / 1.65 * 1.26 inch Non-isolated Terminal (Arduino Side) Supply Voltage: 5.0 ± 0.1V Analog Output: 0 ~ 5.0V Isolated Terminal (Sensor Side) Output Voltage: 5.0 ± 0.2V Analog Input: 0 ~ 5.0V SHIPPING LIST Gravity: Analog Signal Isolator x1 PH2.0-3P Cable x2 https://www.dfrobot.com/product‐1621.html 9‐19‐17 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|