| 数据搜索系统,热门电子元器件搜索 |
|
STTS752E 数据表(PDF) 18 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STTS752E 数据表(HTML) 18 Page - STMicroelectronics |
|
18 / 38 page ![]() Functional description STTS75 18/38 3.1.3 Temperature register The Temperature Register is a two-byte (16-bit) “Read only” register (see Table 9 on page 18). Digital temperatures from the ADC are stored in the Temperature Register in two’s complement format, and the contents of this register are updated each time the A/D conversion is finished. The user can read data from the Temperature Register at any time. When a A/D conversion is completed, the new data is loaded into a comparator buffer to evaluate fault conditions, and will update the Temperature Register if a read cycle is not ongoing. The STTS75 is continuously evaluating fault conditions regardless of READ or WRITE activity on the bus. If a READ is ongoing, the previous temperature will be read. The readable temperature will be updated upon the completion of the next A/D conversion that is not masked by a read cycle. Depending on the A/D conversion resolution, the 9-, 10-, 11- or 12-bit MSBs of the register will contain temperature data. All unused bits following the digital temperature will be zero. The MSB (Bit 15) of the Temperature Register denotes whether the temperature data is positive or negative. A '0' in Bit 15 is positive and a '1' is negative. 3.1.4 Over-limit temperature register (TOS) The TOS Register is a two-byte (16-bit) READ/WRITE register that stores the user- programmable upper trip-point temperature for the thermal alarm in two’s complement format (see Table 10 on page 19). This register defaults to 80°C at power-up (i.e., 0101 0000 0000 0000). The format of the TOS Register is identical to that of the Temperature Register. The 4 LSBs of the TOS Register are hardwired to zero, so data written to these register bits will be ignored. The MSB position contains the sign bit for the digital temperature and Bit14 contains the temperature MSB. The resolution setting for the A/D conversion determines how many bits of the TOS Register are used by the thermal alarm. For example, for 9-bit conversions, the trip-point temperature is defined by the 9 MSBs of the TOS register, and all remaining bits are “Don’t cares.” Table 9. Temperature register format Bytes MS Byte LS Byte Bits MSB THSB TLSB LSB 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 STTS75 SB TMSB TD TD TD TD TD TD 9-bit LSB 10-bit LSB 11-bit LSB 12-bit LSB 00 0 0 Keys: SB =Two’s complement Sign Bit TMSB =Temperature MSB TLSB =Temperature LSB TD =Temperature Data |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |